Thermocouple Wiring
Route the thermocouple wire towards the firewall, taking precaution to keep it away
from hot and moving parts, and then pass it through the firewall by piercing a large
rubber grommet in the firewall beside the brake booster canister.
NOTE: Do NOT cut or splice the thermocouple lead wire, as it is special wire
that provides correct reading to the gauge. Simply coil any excess wire out of
the way.
From under the dash, route the thermocouple to the X-Monitor Control Module.
Install the wires onto the control module as shown in the diagram.
CAUTION: DO NOT MIX UP THESE WIRES, ENSURE YELLOW TO YELLOW
AND RED TO RED OR DAMAGE WILL RESULT AND WARRANTY WILL BE
VOIDED.
Boost Pressure Sender
Duramax (Non LLY)
Locate the turbo wastegate
hose and follow it along to
the plenum.
Remove the turbo
wastegate from the barb
fitting on the plenum and
install the rubber hose end
of the supplied boost fitting
assembly onto the barb.
Install the turbo wastegate
onto the barb of the
supplied boost fitting
assembly.