![BBV Tx1000 Installation Manual Download Page 20](http://html1.mh-extra.com/html/bbv/tx1000/tx1000_installation-manual_2714052020.webp)
TX1000 Manual V8 September 2013
20
Enabling/Disabling the Alarm package
The alarm package can be enabled/disabled; for example at night
when the building is empty the alarms can be enabled via a
keyswitch fitted across alarm contacts pins 1 and 2.
Closed switch = alarm package disabled
Open switch = alarm package active
Local alarms to the receiver will NOT be disabled using this link.
Note:
Cutting the switch cable will activate the alarm package.
Action on alarm
Each alarm can be programmed to switch monitor 1 to display a specific camera and go to a preset position
for that camera. An alarm message is displayed on the screen and the alarm output relay closes for a
programmed length of time.
If the sequence is running then the alarm time is added to the sequence time, and the sequence continues
to run after the alarm times out.
If the sequence is not running, the alarm message and selected camera remain on monitor 1 until a manual
camera selection.
The camera selected and the preset command issued is programmable via the keypad. Press the
key and select ’11’ with the numbers followed by the camera button.
The following message then appears on screen:
Program Alarm?
Enter the alarm number you wish to program followed by the camera button. Then the following prompt
appears:
Camera?
Enter the camera number you wish to use when the alarm is triggered. Followed by the camera button
Preset?
Enter the number of the Preset you wish to go to when the alarm is triggered. Followed by the camera
button.
Keyswitch
Installer fitted keyswitch to
control alarm package
ALARM CONTACTS