Programming manual SCU-series
HB-37500-820-10-12F-EN SCU Programming manual
Page 134 of 252
Status: 19.03.2021
This view shows a connection of the device with the superordinate SPC. In the local network, the
fieldbus is activated separately for each device.
The use of the fieldbus can be safe, non-safe or both. The use can be selected in the properities
window. The design of line for the fieldbus changes according to the selected use.
Safe use is indicated by a solid red line.
Non-safe use is indicated by a dashed line:
If both possibilities are used, this is inidicated by a double orange-blue line:
4.11.2.3. Configuration
To configure the properties of this network, the user can either click on the fieldbus line, or he can
select the fieldbus in the browser via the properties window with defined propertiesThe properties
of this network can be configured with the user clicking on the fieldbus line or with the user
selecting the fieldbus in the browser library via the properties window with predefined propertiest.
For information transmission via this bus, a fixed size is available (e. g. 98 bit). This information (e.
g. velocity, position in the form of bytes, int 16, int24 or int32, or types defined by marks
)”
can be
shared with the process data (e. g. velocity, position in the form of bytes. The other part can also
be used for the transmission of the logic information. Network configuration depends on the preset
profiles.
The properties window for the different protocols is shown below.