5.0 DISPLAY
6.0 SYMBOLS AND INDICATORS
Symbol
Description
Scale is in the zero position
Weighing result is stable
kg , lb, oz or lb.oz
Active weighing unit
Battery is weak
Net weight is being displayed
Hold
Display is held as per the Hold parameter setting
7.0 BATTERY
When the battery needs charging a symbol on the display will turn
on. The battery should be changed when the symbol is on, or
connect the power supply module to the rear of the indicator and
apply power. The scale need not be turned on.
8.0 BACKLIGHT
The backlight for the LCD can be set by the user to always off,
always on or automatic (on only when the scale is in use or a key is
pressed). See setting of the parameter in section 13.1.2.
5
is set to “
Hod 2
” or “
Hod 3
”.
1.Hti 0 :
Holds the display for an infinite time limit
2.Hti 1 :
Holds the display for 15 (1 x 15) seconds
3.Hti 2 :
Holds the display for 30 (2 x 15) seconds
4.Hti 3 :
Holds the display for 45 (3 x 15) seconds
5.Hti 4 :
Holds the display for 60 (4 x 15) seconds
Press the
key to confirm the selection and move back tofirst
parameter or press
to exit the parameter setting.
HOLD AND PRINTING TABLE
:
trn 1
trn 2
trn 3
Hod
1
USB communication
is off. Hold is off.
key has no
function.
USB prints
continuously. Hold
is off.
key
has no function.
USB prints when
is pressed.
Hold function is
disabled.
Hod
2
USB communication
is off. Hold occurs
automatically when
the weight is stable.
Hold is released if
is pressed or
time expires as per Hti
setting.
USB print
continuously. Hold
occurs
automatically when
the weight is stable.
Hold is released if
is pressed or
time expires as per
Hti setting.
USB prints and hold
occurs automatically
when the weight is
stable.
key is
pressed print will occur
again. Hold function is
released if the key is
pressed again or time
expires as per Hti
setting.
14