VarioRec 6
6
1
2
1
1
2
2
3
3
3
4
4
4
4
4
5
5
5
3
Translation of the original instructions
Pressure-sensitive bedside mat
to detect patients who wander or fall
1
Safety instructions
2
Product description
The CareMats with 869.2125 MHz VarioMobil
®
radio transmitters are com-
patible with the VarioRec
®
radio receivers from Lehmann Electronic GmbH.
The radio receivers (not part of the scope of delivery) can receive the radio
signals from the radio transmitters on the social alarm frequency bands ap-
proved for this purpose, and relay them to a cable-connected or wireless call
system, for example. Detailed information about this device and other com-
patible social alarm frequency devices can be found on the following web-
sites:
www.lehmannweb.de
2.2
Areas of application and function
The CareMat is designed for use in nursing homes, hospitals, psychiatric
wards, and home care. Care and supervision of accident-prone patients and
those with dementia require significant time and financial investments
from caregivers. CareMat is an ideal addition to reduce risks that may
arise from wandering patients.
The CareMat with radio transmitter is placed beside a patient's bed, as a
pressure-sensitive detector. The radio receiver is connected to the existing
call system. As soon as a person gets out of the bed and steps on to the
CareMat, the mat sends a signal so the call system can trigger an alarm.
The wireless radio system facilitates handling around the patient's bed.
If the CareMat is not needed during
the day, it can be stored underneath
the bed.
CareMat should be centrally aligned
next to the bed so it is impossible to
bypass.
Connect the associated radio recei-
ver to the call system.
• Do not bend CareMat during transport, storage or installation.
• CareMat must be stored flat in a clean, dry location with tempe-
rature range 0 °C to +55 °C.
• Do not place any heavy loads on the CareMat and do not stack
more than 10 packed mats on top of each other.
• The CareMat can be cleaned using commercially available disinfecting
and cleaning agents with max. 70 vol% alcohol.
No corrosive agents should be used.
• The CareMat is neither autoclavable nor can it be disinfected using
steam.
3
Day to day operation
4
Cleaning and disinfecting
5
Transport and storage
2.1
Radio system description
Housing with radio transmitter
Chamfered, wheelchair-accessible edges
Non-slip surface with stud texture design
1
2
3
Carrying handle
Active switching zone
VarioRec
®
radio receivers (not part of the scope of delivery)
4
6
5
CareMat A01T L869
CareMat A11T L869
1100 x 700 mm
CareMat B01T L869
CareMat B11T L869
700 x 400 mm
CareMat C01T L869
CareMat C11T L869
1100 x 700 mm,
semi-circular
VarioRec 6
VarioRec 6
CareMat
with 869.2125 MHz VarioMobil
®
radio transmitter
(social alarm frequency in accordance with DIN EN 50134)
DE
EN
FR ES
IT SV
335023D
03/21
• Read these operating instructions thoroughly before putting the device into operation
and keep them for future reference.
• Not a safety component in accordance with the EU Machinery Directive must not be
used for personal protection or EMERGENCY STOP function.
• Do not use this product other than for its specified application.
• Failure to follow these safety precautions may cause damage to device or objects, se-
rious personal injury, or death.
• Observe all applicable local, national, and international safety standards,
codes, and laws.
• After accessing the inside of the device, ensure the cover/protection seal is closed
tightly to achieve designated protection rating.
• Warranty claims will be invalid in the event of any damage to the product, to goods or
persons that is due to failure to observe these instructions.
Instructions for nursing staff
• The CareMat operates purely as a support for the nursing staff, but is not a substi-
tute for them.
• The functionality of the CareMat is to be checked each time that it is used.
Notes for the installer
• The electrical installation work and commissioning of the product may only be car-
ried out by a qualified technician.
• Avoid touching any electronic components.
• ESD safety rules should be observed.