background image

8

These features and specifications for the LP Cylinder MUST be present. If you exchange the LP cylinder, make sure 

the new tank also complies with all the specifications listed here:

45.72cm/ 
18-in Tall

31.75cm/12.5-in Diameter

LP Cylinder Valve 

(Trilobular Handwheel 
indicates OPD is present)

Type-1
Outlet

Protective 
Collar

Safety 
Relief
Valve

Protective 

Cap

Place dust cap on cylinder valve outlet whenever 
the cylinder is not in use. Only install the type 
of dust cap on the cylinder valve outlet that is 
provided with the cylinder valve. Other types of 
caps or plugs may result in leakage of propane.

CAUTION

9.1 Kg/20 lbs capacity;
31.75cm/12.5-in diameter x 45.72cm/18-in tall
Type-1 gas cylinder valve outlet to accommodate 
the hose and regulator supplied with this 
appliance. The Type-1 valve must prevent gas 
flow until a positive seal is obtained.
Over-Filling Protection Device (OPD) - indicated 
by a trilobular handwheel.
Collar to protect the cylinder valve. Required of 
any cylinder whose capacity is in excess of 
1 Kg/2.2 lbs.
Safety Relief Valve
Protective cap
Cylinder must be arranged for vapor withdrawal 

(not shown)

.

To Connect the Hose Valve Regulator to the LP Cylinder:

•  Before attaching the Type-1 Connector to the tank, ensure the LP 

Cylinder Valve is fully turned off (closed).

•  Confirm the Control Knob on the HVR is turned off (closed) as well.
•  Place the LP cylinder upright, and locate it at least 50.8cm/20-in from 

the appliance. (See 

Placement of Cooker)

•  Remove the Protective Cap from the Type-1 Outlet.
•  Screw the ACME Type-1 Connector on the HVR to the Type-1 Outlet 

on the LP Cylinder by hand and tighten to a full stop. Do not use tools.

 To Disconnect the Regulator from the LP Cylinder:

•  Before disconnecting the regulator from the tank, ensure the LP 

Cylinder Valve is fully turned off (closed).

•  Confirm the Control Knob is turned off (closed) as well.
•  Disconnect the Type-1 Connector on the regulator from the Type-1 

Outlet on the LP Cylinder.

•  Replace the Protective Cap over the Type-1 Outlet.

Upright

Position

Hand 

tighten 

only

Replace 

Dust Cap

Summary of Contents for 200-480

Page 1: ...s Instruction Manual contains important information necessary for the proper assembly and safe use of the appliance You must carefully read and follow all warnings and instructions before assembling a...

Page 2: ...immediately turn the burner or gas supply OFF If the temperature exceeds 200 C 400 F or if oil begins to smoke immediately turn the burner or gas supply OFF and wait for the temperature to decrease t...

Page 3: ...pets away from the cooking area at all times Introduction of water or ice from any source into the oil grease may cause overflow and severe burns from hot oil and water splatter When frying with oil...

Page 4: ...plication improper installation or improper maintenance or service by you or any third party or failure to perform normal and routine maintenance on the appliance as set out in this owner s manual In...

Page 5: ...ust be a minimum of 8 cm 3 in between the water level and top of the vessel D Remove the food product from the vessel and either mark the water level on the side of the vessel or measure the amount of...

Page 6: ...rn burner upside down and position burner into U of support bar with end of burner turned to the front Insert mounting bolt into center hole of bar Holding burner in place position heat shield over bo...

Page 7: ...d hole of the burner Screw the male connector into the burner until the spring is mostly compressed and connection is firm The air shutter should be allowed to turn freely but still hold its position...

Page 8: ...losion which could cause property damage personal injury or death DANGER CARBON MONOXIDE HAZARD This appliance can produce Carbon Monoxide an odorless and poisonous gas Never operate this appliance in...

Page 9: ...Collar to protect the cylinder valve Required of any cylinder whose capacity is in excess of 1 Kg 2 2 lbs Safety Relief Valve Protective cap Cylinder must be arranged for vapor withdrawal not shown T...

Page 10: ...the LP Cylinder B Press the black POWER button both lights will blink once C Press the red START button green Gas Flow light will remain on D Allow the timer to complete the entire 15 minute cycle not...

Page 11: ...nto food This will cause an incorrect temperature reading DO NOT attempt to use your thermometer if it is not working properly Replace the thermometer if it appears to be damaged or does not accuratel...

Page 12: ...DO NOT use a flashlight to check for bubbles 5 First inspect areas A D for growing bubbles 6 Next turn on open the Control Knob and start the Timer to permit gas to pass through the timer and hose In...

Page 13: ...es ANSI NFPA 58 or Natural Gas and Propane Installation Code CSA B149 1 Propane Storage and Handling CSA B149 2 Keep the cooking area clear and free of any combustible material such as spare LP tanks...

Page 14: ...ol the temperature of the cooking liquid within the pot The temperature must be controlled manually by observing the thermometer and adjusting the flame with the Control Knob WARNING Lighting the appl...

Page 15: ...le the burner by removing the serrated nut and unscrewing the mounting bolt from the center of the burner If the red Low Battery light becomes lit during use the batteries need to be replaced Wear eye...

Page 16: ...urn appliance off and wait for it to cool down Perform Gas Leak Test to confirm gas leak Replace any damaged or faulty parts Turn up open LP Cylinder Valve all the way Inspect LP tank burner and HVR a...