background image

 

 

gases and/or vapors are present. 
 

 

Warning 

If the user of the respirator feels dizzy or uncomfortable or can 
smell/taste anything, he should abandon the contaminated area 
immediately and check the unit.   

3.1.2 Usage limitations filter element 

Used filter elements cannot be cleaned. 

Warning 

Never attempt to clean a filter element; the filter media may be 
damaged, resulting in loss of protection. 

3.1.3 Charging batteries 

The battery is supplied partially charged. The charging time for 
a fully discharged battery is approximately 5 hours. To ensure 
maximum  working  time,  it  is  recommended batteries  are  fully 
charged  before  use.  The  automatic  setting  of  the  charger 
prevents  damage  to  the  batteries  when  the  charging  time  is 
exceeded.  Under  normal  circumstances  the  battery  can  be 
charged  and  discharged  approximately  500  times.  After  the 
battery  is  completely charged,  the  charger will  switch  over  to 
trickle  charging.  This  will  expand  the  lifetime  of  the  battery 
beyond 500 charge cycles.   

3.2 Switching on 

The unit can be switched on by pushing the ON/OFF button for 
three seconds. A sound signal will be heard to indicate that the 

electronic control unit is working correctly. 
 

3.3   During use 

After turn on, the system runs and self-checks first at full speed 
for 3 seconds. After you can set the low-medium-high air flow 
speed. 
Note: the LED light is on for 5 seconds, if you need to adjust the 
air flow later, first press the “ON/OFF/SET” button to turn on the 
light, and then set the air flow speed. During usage, if the air 
supply drops or fails entirely, leave the work area immediately. 
If the sound signal for low battery (two continuous short beeps 
repeatedly) is heard or a clogged filter element (a single short 
beep repeatedly), leave the workroom immediately, and check 
the unit in accordance with section 6. 

3.4   After use 

Press the button "ON/OFF/SET" for 2 seconds, when you see         
the three LED lights flash twice, the device is turned off. 

3.4.1 Cleaning and disinfecting 

After each session clean the unit, do not use any solvent. During 
cleaning ensure that no water is allowed to enter the apparatus. 
The unit must not be immersed. Dry the unit with a cloth and/or 
leave it to dry in the open air. 

Advice 

For reasons of hygiene each operator should be equipped with 
their own hood or mask. 
 