AC Electrical System
Your boat uses a 120v/60Hz AC (alternating current) system.
Τ
he AC
system can be energized by shore power or optional generator power.
This system is designed so that ship’s power and shore power sources
cannot supply power simultaneously.
The AC panel’s master circuit breakers provide power source selec-
tions to the accessory breakers that are directly below the designated
master breaker. After activating AC power, individual breakers must
be activated to supply power to the accessories you wish to use.
Shore Power
Your standard-equipped boat features one 120v/30 amp shore power receptacle, located on the port side of the deck.
If your boat is equipped with an optional air conditioning system, a second 30 amp inlet has been installed next to the
existing shore power inlet. When both inlets are installed, the inlets are labeled line one and line two, which corre-
sponds to the line one and line two master breakers on the AC panel.
This system is designed so that each line oper-
ates independent of each other.
AC PANEL LOCATION
(VIEW OF GALLEY)
AC PANEL
(INSIDE)
• SYSTEM DAMAGE HAZARD! When using shore power or
generator power, the simultaneous operation of several AC
accessories can result in an overloaded circuit. It may be
necessary to turn off one accessory while operating another.
• WATER HEATER DAMAGE HAZARD! Do not energize
the water heater electrical circuit on the AC panel until the
heater is completely filled with water. Even momentary
operation in a dry tank will damage the heating elements.
Warranty replacements will not be made on elements or
tank damaged in this manner.
C AUTI ON!
!
NOTI C E
Some dockside installations may be rated less than 30 amps, therefore, you may need to
purchase lower amp adapters. Whenever a lower amp adapter is used, however, there will
be a corresponding drop in supplied power from the dockside system.
30 AMP SHORE
POWER INLET
30 AMP SHORE POWER INLET
(AIR CONDITION OPTION)
SHORE POWER INLET LOCATIONS
PORT
STANDARD
Summary of Contents for Ciera
Page 1: ......
Page 6: ......
Page 37: ...Appendix A Wiring Schematics 31 3055 EL Ciera Sunbridge Owner s Manual Supplement Hull Harness...
Page 39: ...Appendix A Wiring Schematics 33 3055 EL Ciera Sunbridge Owner s Manual Supplement Deck Harness...
Page 49: ...Owner s Notes...
Page 50: ...Owner s Notes...
Page 51: ......
Page 52: ...Part Number 79555 Bayliner P O Box 9029 Everett WA 98206 360 435 5571...