Chapter 6: Plumbing
45
Freshwater System Winterization
1. Turn
Off
the water heater breaker switch.
NOTE:
Tag
or
Mark
the water heater breaker switch to prevent it from being turned
On
while the water heater
tank is empty.
2. Turn
On
the freshwater pump switch.
3.
Open all
of the faucets and showers and let the freshwater system drain completely.
4. Turn
Off
the freshwater pump switch.
All
of the remaining water
must
be removed from the water lines. There are two ways to remove the remaining water
from the lines:
•
Compressed Air
•
Gravity Draining
Compressed Air
You
must
have an air compressor with an air hose and
an air nozzle.
1. Remove the water line from the outlet side of the
freshwater pump (opposite side from filter).
2.
Open
the faucet that is furthest away from the fresh-
water pump.
3. Place the air nozzle against the end of the just
removed water line and blow air through the system.
4. When water stops coming out of the faucet, stop the
air and
Close
the faucet.
5. One at a time, repeat this process on
all
faucets and
showers.
Gravity Draining
1.
Open
all
faucets and showers.
2. Remove the drain plug from the tee fitting on the
freshwater tank.
3. When the water has stopped draining from the
freshwater tank and the water lines, replace the
drain plug.
FRESHWATER SYSTEM DAMAGE HAZARD!
•
A faucet
MUST
be
Open
when compressed air is blown through the freshwater system.
•
NEVER
blow compressed air through the water system when
ALL
of the faucets are
Closed
.
CAUTION
!
TYPICAL VIEW
NOTE: LOCATION OF TEE FITTING
& DRAIN PLUG MAY VARY
Summary of Contents for 255 Cruiser
Page 1: ......
Page 2: ......
Page 19: ...255 Cruiser Owner s Manual Supplement 13 Chapter 2 Locations Exterior Views Hull Views...
Page 20: ...Chapter 2 Locations 255 Cruiser Owner s Manual Supplement 14 Deck Views...
Page 85: ...255 Cruiser Owner s Manual Supplement Chapter 11 Electrical System 79 12 Volt DC Deck Harness...
Page 87: ...255 Cruiser Owner s Manual Supplement Chapter 11 Electrical System 81 110 Volt AC Hull Harness...
Page 91: ......
Page 92: ...Part Number 1959031 Bayliner 17825 59th Ave NE Arlington WA 98223 360 435 5571...