background image

TESTING

22

®

23

TESTING

 Before Meal

 

After Meal

 

Time After Meal

 

Don’t Feel Right

 Sick

 Stress

 Activity

 Go 

Back

ADD NOTES

OK

10:30 | 13.10

Bolus

Bolus

Reminder

Reminder

Notes

Notes

High Blood Sugar

14.0

mmol
    L

Low Blood Sugar

3.8

Low Blood Sugar

APPLY BLOOD

 WARNING

•  Do not calibrate your continuous glucose monitoring device from a control result
•  Do not calculate a bolus based on a control result

14.0

High Blood Sugar

•  A screen with large orange numbers alerts you that 

your blood sugar is high.

 WARNING

Shake the control solution well before testing.  

High and Low Blood Sugar Alert Scr

eens

Contr

ol Solution T

esting

  High and Low Blood Sugar Alert Screens

Your meter has been preset with a low blood sugar (hypoglycaemia) value of 3.9 mmol/L 
and a high blood sugar (hyperglycaemia) value of 13.9 mmol/L. These are the preset values, 
but can be customized by you and/or your health care professional. You can change the 
High and Low Alert levels under Main Menu, Setup option (see page 51).
If your blood sugar reading is under your low blood sugar alert level:

•  A screen with large orange numbers alerts you that 

your blood sugar is low.

If your blood sugar reading is over your high blood sugar alert level:

•  If AutoLog is ON and you did not mark your result 

before the high or low alert appeared, select 

Notes

• Press the 

 or 

 button to scroll through the choices.

• Press 

OK

 when your choice is highlighted.

  Testing in the Dark 

Your meter has a lighted test strip port to help you test in the dark. 
•  With the meter off, give the top 

Menu

 button two quick presses to turn on the test strip 

port light. 

•  Insert a test strip and the display screen appears. 
•  Once blood is applied to the test strip, the light goes off. 
•  Continue with your test. 
•  Two quick presses of the top 

Menu

 button also turns off the light.

  Control Solution* Testing

CAUTION:

 Check the expiry date on the test strip bottle and the expiry date and 

discard date on the control solution bottle. DO NOT use expired materials.

 Quality Control

You should perform a control test when:
•  using your meter for the first time
•  you open a new bottle or package of test strips
•  you think your meter may not be working correctly
•  you have repeated, unexpected blood glucose results

Control solutions are available separately if not included in the meter kit. Always use 
C

ONTOUR

 N

EXT

 control solutions from Bayer. Other brands could present incorrect results. If 

you need help locating C

ONTOUR

 N

EXT

 control solutions from Bayer, contact Bayer Diabetes 

Support. Please see back cover for contact information.

1. 

Remove the test strip from the bottle and firmly snap the lid closed. 

2. 

Hold the test strip with the grey square end facing up.

3. 

Insert the grey square end of the test strip into the test 
strip port until the meter beeps.

4. 

You will see the 

Apply Blood

 screen. The meter is now 

ready for you to test.

CAUTION: 

Use only C

ONTOUR

®

N

EXT

 control solution from Bayer with your 

C

ONTOUR

®

N

EXT

 LINK 2.4 blood glucose monitoring system. Using anything other than 

C

ONTOUR

 N

EXT

 control solution can cause inaccurate results.

* Control solution may not be included in all meter kits. Contact Bayer Diabetes Support for information 

on obtaining control solution. See back cover for contact information.

84647013_CntrNextLINK2_4_UG_EN_FpBp_v3.indd   22-23

84647013_CntrNextLINK2_4_UG_EN_FpBp_v3.indd   22-23

3/18/13   8:05 AM

3/18/13   8:05 AM

Summary of Contents for Contour next Link 2.4

Page 1: ...nges Alt 2 03 08 13 copy changes Alt 3 03 18 13 copy changes March 18 2013 Bayer HealthCare Contour Next Link 2 4 mmol User Guide English 909866 6220 Parent BAN 84584321 7 5 H x 6 5 W 10000012465 REV...

Page 2: ...ONTOUR NEXT LINK 2 4 user guide the MICROLET 2 lancing device package insert your Medtronic device user guide and all instructional materials provided in your meter kit before testing Please follow al...

Page 3: ...the USB extension cable The meter is fully charged when the test strip port light stops flashing and turns off NOTE Your meter can Rapid Charge After 1 minute of charging you can unplug the meter and...

Page 4: ...ring System from Bayer Your CONTOUR NEXT LINK 2 4 wireless blood glucose monitoring system from Bayer only works with CONTOUR NEXT test strips from Bayer WARNING Keep out of reach of children Accident...

Page 5: ...to scroll through the list faster Button OK Button Button CAUTION Unplug meter from charging source before beginning Setup Using the Main Menu Initial Setup 1 Before use fully charge your meter See pa...

Page 6: ...nsulin pump now If you press Skip you will be asked to accept or change the date and time To change follow instructions starting on page 45 step 5 Return to Initial Setup page 10 step 21 when set 8 In...

Page 7: ...her nearby Medtronic devices are NOT in search mode Use the down arrow to scroll to the next page Use arrow buttons to scroll to Continue Press Select button Select Search on your meter The search may...

Page 8: ...you selected Change press the or button to select your High Alert level This can be set between 7 0 20 0 mmol L Press OK 24 Press the or button to select your Low Alert level This can be set between 3...

Page 9: ...e set inside your selected Alert level s For additional information you may contact Customer Service Contact information for Bayer Diabetes Support is on the back cover WARNING Talk to your health car...

Page 10: ...ght again After a total of 3 minutes of inactivity the meter will turn off Preparing the Test Strip 4 Twist off the round protective lancet cap Save it for disposing of the used lancet 5 Replace the g...

Page 11: ...vels within 2 hours after a meal No Mark You can select No Mark if you are testing at times other than before or after a meal or fasting 9 3 Your test result appears as a large number and then changes...

Page 12: ...ar is changing rapidly after a meal insulin dose or exercise If you are unable to feel symptoms of low blood sugar hypoglycaemic unawareness If you get alternative site blood sugar results that do not...

Page 13: ...es When you have completed your test remove the test strip from the meter Press and hold the top Menu button to turn off the meter The meter also turns off after 3 minutes of inactivity a b 2 Place th...

Page 14: ...ort light Insert a test strip and the display screen appears Once blood is applied to the test strip the light goes off Continue with your test Two quick presses of the top Menu button also turns off...

Page 15: ...e your test result is displayed the AutoLog screen appears However if your result is above your High Alert setting or below your Low Alert setting you will always see your result in 5 seconds without...

Page 16: ...27 Preset Bolus First follow Steps 1 2 and 3 on page 26 4 Next choose the Preset Bolus you wish to send to your pump NOTE Preset bolus is set on your pump 6 Press Yes to send the bolus to your pump 5...

Page 17: ...an be set after testing OR from the Setup Menu see page 43 A reminder can be set in 15 minute increments from 15 minutes to 23 hours 45 minutes 1 With the test strip still in the meter press Reminder...

Page 18: ...ted to the pump AND the Remote Bolus feature must be turned ON at the pump Remote Bolus is ON by default on the pump For the steps on sending a bolus to your pump see page 25 Logbook The Logbook conta...

Page 19: ...ter has been preset to 14 day averages but you can change this under Trends Range in the Setup Menu see page 51 Your 90 day average is not intended to be reflective of your HbA1c result Your screen wi...

Page 20: ...ess Select button NOTE If your pump screen turns off press any button to turn it back on 7 In the Utilities menu use the down arrow to scroll to Device Options Press Select button 8 In the Device Opti...

Page 21: ...step you select how the date and time are displayed on your meter NOTE Your pump automatically controls the date and time If they need to be changed on your pump see your MiniMed insulin pump user gui...

Page 22: ...you would like to Connect now Press Yes 5 Press OK Put the meter down 6 Pick up your pump Press any button to turn screen on then press the Menu button Use the down arrow to scroll to Utilities Press...

Page 23: ...Press OK 19 Press OK to confirm and return to the Setup Menu Connecting to the Pump Using Manual Connect Connecting to the Pump Using Manual Connect 13 The next screens on both devices confirm that m...

Page 24: ...the Send Option set to Never if you do not want to create a wireless signal for example if you have been asked to turn off all electronic devices on an aircraft 1 Press and hold the top Menu button t...

Page 25: ...der Date and Time Turning Off a Reminder To turn off a reminder you can use the Setup Menu or do a blood sugar test within 15 minutes of the reminder time To use the Setup Menu 1 Press and hold the to...

Page 26: ...the date as it appears on the meter Press Sync to synchronize the meter with the date and time that is set on the Pump Sound Turning the Sound On Off Sound is ON when you receive your meter Some error...

Page 27: ...ts are your personal ranges for your blood sugar results With AutoLog OFF you have a single Target range With AutoLog ON you have Target ranges for Fasting Before Meal and After Meal WARNING Talk to y...

Page 28: ...e of your HbA1c result 3 Press the button to highlight Trends Range 4 Press OK to select 6 Select 7 14 30 or 90 Day by using the button and then press OK A screen confirms your choice 3 Press the butt...

Page 29: ...a code that enables them to verify certain settings It is not for use any other time Please see back cover for contact information 4 Press the or button to select the language you prefer Press to see...

Page 30: ...battery charges the test strip port light flashes slowly Press the top Menu button at any time to display the charging status Plug the meter into your wall charger or into the USB port of your comput...

Page 31: ...sion Confusion Passing Out Irritability Seizure Extreme Hunger Dizziness Frequent Urination Excessive Thirst Blurred Vision Increased Fatigue Hunger Shortness of Breath Nausea or Vomiting Very Dry Mou...

Page 32: ...he back of the meter 2 Locate the test strips expiry date on the bottle 3 Check the battery symbol on the screen See page 54 Battery Status Principles of the Procedure The CONTOUR NEXT LINK 2 4 blood...

Page 33: ...ce do not use the CONTOUR NEXT LINK 2 4 meter near cellular or cordless telephones walkie talkies garage door openers radio transmitters or other electrical or electronic equipment that are sources of...

Page 34: ...medical care in diabetes 2012 Diabetes Care 2012 35 Suppl 1 S11 63 7 Longo D L et al Harrison s Principles of Internal Medicine 18th Edition 2011 http www accessmedicine com 8 Data on file Bayer Healt...

Page 35: ...meter when used with any test strips other than CONTOUR NEXT test strips and therefore makes no warranty of the performance of the CONTOUR NEXT LINK 2 4 meter when used with any test strips other than...

Page 36: ...kers AutoLog 10 Memory Logbook 31 Menu Button 4 Meter 4 Disposal 55 Overview 4 Meter Care 62 mg dL milligrams per decilitre iii mmol L millimoles per litre iii MiniMed Insulin Pump 4 Notes 30 Adding t...

Page 37: ...20 111 Ireland www bayerdiabetes ie 2013 Bayer All rights reserved 84647013 Rev 01 13 All other trademarks are the property of their respective owners Bayer the Bayer Cross CONTOUR GLUCOFACTS and MICR...

Reviews: