26
User’s guide
ES
FR
ENg
Weight-tare indicator
BR70
User’s guide
27
BR70
Weight-tare indicator
ENg
FR
ES
7. CAlIBrAtION
The scale can be calibrated using the following procedure. For a more detailed method of calibrating the scale it will be necessary to
enter the secure Programming Menu. See detail in section 12.
The BR70 weighing indicator can calibrate using either metric or pound weights, depending on the weighing unit in use before calibra-
tion. The display will show either “kg” or “lb” to identify the weights expected.
PREOCEDURE
› Turn the power off.
› Turn the power back on, during the counting from 9 to 0 press the
key.
› The display will show “CAL” for a few seconds. While it is showing “CAL” press the
,
and
keys in sequence to enter the
Calibration section. The display will show “unLoAd”.
› Remove any weight from the platform. After stable indicator on, press the
key.
› The display will show last calibrate weight value, you can use
,
,
, key input new calibrate weight value (use
,
key to move active digit, use
key to change value), after you setting, press
key to sure, display will show “LoAd”. Place the
calibration weight on the scale. Press the
key.
› If the calibration is acceptable the display will show “PASS” and then return to normal. If an error message is shown try calibration
again as a disturbance may have prevented a successful calibration.
› If the problem persist then contact your dealer.
› After calibration the scale should be checked to verify the calibration and linearity is correct. If necessary repeat calibration, especially
be certain the scale is stable before accepting any weight.
8. ErrOr COdES
ERROR CODES
DESCRIPTION
RESOLUTION
-----
Over range
Remove weight from the scale.
If the problem persist contact your dealer or Baxtran scale for assistance.
Err1
Date Setting Error
Enter date using correct format and reasonable values.
Format: yy:mm:dd
Err2
Time setting Error
Enter time using correct format and reasonable values.
Format: hh:mm:ss
Err4
Zero Setting Error
The scale was outside the normal zero setting range either when it was
turned on or when the
key was pressed. Remove weight from the scale
and try again. Use the
key to set the display to zero value. If the problem
persist contact your dealer for assistance.
Err5
Keyboard short
Keyboard damaged
Err6
A/D out of range
The values from the A/D converter are outside the normal range. Remove
weight from the scale if overloaded, make sure the pan is attached. Indicates
the load cell or the electronics may be faulty. If the problem persist contact
your dealer for assistance.
Err9
Unstable, can’t
return to zero
When turn on the power, if internal counts is not stable, display will have “Err
9”, please check the platform and load cell. If the problem persist contact your
dealer for assistance.