– 15 –
FLUSH TIME
Water is circulated through the water chiller bypass line to the chiller tank. The
fl
ush time setting allows
for a certain amount of time for the meter to
fi
nd the set temperature, /- 2°F (1°C). The default
fl
ush time is 120 seconds.
Changing Flush Time
The
fl
ush time should be set long enough so the desired set temperature can be reached before switching
from the bypass line to the dispensing hose.
1.
Press
SET
TEMP.
2. Enter 32 using the numeric keypad.
3.
Press
SET
AMOUNT.
4. Enter 95505 using the numeric keypad. The WATER AMOUNT SETTING window displays
955 lbs 05 oz.
5. Press START/RESUME. The WATER TEMPERATURE SETTING window displays the current
fl
ush
time in seconds.
6. Enter a new
fl
ush time value between 60 and 240 using the numeric key pad.
7. Press START/RESUME to save this setting.
SHUTDOWN
Shutdown procedures should be followed when the water meter is not used for an extended period of
time.
1. Close the hot and cold water supply valves.
2. Empty any remaining water from the dispensing hose.
3. Place the dispensing hose on the hook located on the side of the water meter.
4. Unplug the power cord from the electrical outlet.
CLEANING
Disconnect the electrical power to the machine and follow lockout / tagout
procedures.
• Clean the hand held temperature probe daily with warm, soapy water. Follow with a warm water
rinse. Wipe with a soft, dry cloth.
• Clean the stainless steel surfaces with a damp cloth and polish with a soft, dry cloth. To remove
discolorations, use a nonabrasive cleaner.
• Clean the control panel with a damp cloth only.
• Do not use any cleaners containing oil or other
fl
ammable ingredients.
• Do not spray the water meter with a hose, pressure washer or steam cleaner.