– 10 –
RETARDER/ PROOFER (Auto Mode)
This operation will put Retard and Proof in one operation. The automatic Retard/Proof operation can be
programmed for either a single day or seven days. (See chart for the parameter value setup.) After one
operation cycle (Retard and Proof) is finished, the unit now runs Proofer mode. To resume the next day
program, the operator must go to RETARDER/PROOFER Mode and press "Start/Retard/Proofer" arrow
button.
NOTE:
Rest period and Recover time are setup times before the unit enters the proof stage. (See chart
for the default value.)
The operator must select "CHANGE MODE" arrow button, "RETARDER/PROOFER" arrow button, then
press "Start/Retard/Proof" arrow button to resume the program for the next day.
• Follow the steps below to program automatic Retard/Proof operation.
After pressing Review/Edit
Settings, the next screen on the
LCD is shown here (Fig. 8).
Review/Edit Settings>
Start Retard/Proof>
CHANGE MODE>
RETARDER/PROOFER
Today is Friday
Change DAY? >
[NEXT]
7 DAY PROGRAM
In Figure 8, the LCD displays "7 DAY PROGRAM" because the parameter P15 value is set to "1".
NOTE:
This step is for service only. If single day program is preferred, see Operating Parameter Setup
to change P15 value to "0".
If day is not correct, then press "Change DAY?" arrow button. The LCD next screen displays the option
to select days as shown below.
DAY
DAY >
[NEXT]
Today is Friday
Use the arrow buttons to change
day. Then select NEXT button
or arrow button to set the clock
(Fig. 9).
To enter the RETARD/PROOF
operation, press "Review/Edit
Settings" arrow button (Fig. 7).
Fig. 7
Fig. 8
Fig. 9
Review or edit new settings.
Press here to change day.