13
oce_010621_0900
oce_010621_1000
oce_010621_1
100
examples of installation with LAS-type fl ues
examples of installation with vertical ducts
Installation can be performed either with a pitched roof or with a
fl at roof using the stack and the special tile and sheath available on
request.
For more detailed instructions on how to fi t the accessories, please
refer to the technical notes provided with the accessories.
4.3.2 twin pipe ducts
This type of duct can be used to discharge fl ue gases both outside the
building and in single fl ues. The air for combustion can be drawn in at
different places to those for discharge.
The splitter is an accessory comprising an exhaust reduction coupling
(100/80) and a shutter air intake coupling.
The seal and the screws of the air intake coupling are the ones re-
moved beforehand from the plug.
For more detailed instructions on how to fi t this accessory, please refer
to the technical notes provided with it.
L max = 4 m
(L
1
+L
2
) max = 3 m
L max = 4 m
L max = 4 m
(L
1
+L
2
) max = 3 m
L max = 3,5 m