![Baxi NUVOLA PLATINUM + Instruction Manual For Users And Fitters Download Page 33](http://html.mh-extra.com/html/baxi/nuvola-platinum/nuvola-platinum_instruction-manual-for-users-and-fitters_2711876033.webp)
33
USER Section
(en)
7219840.02 (1-03/16)
2. ACCESS TO THE PARAMETER CONFIGURATION MENUS
KEY TO DISPLAY (see figure to side)
a
Date: day, month, year
b
Day of the week
c
Pressure in boiler / heating circuit
d
Clock: hour and minutes
To access the list of configuration menus, proceed as follows (consult the
"Description of Symbols" section):
C
B
to select the required menu;
B
to confirm or
C
to
exit without saving.
The list of configuration menus is:
• Information (INFORMATION MENU)
• Set time and date (TIME AND DATE MENU)
• Operator unit (CHANGE LANGUAGE)
• Time central heating (HOURLY PROGRAMMING)
• Time central heating CH3
•
Time hot water
•
Time auxiliary
•
Holiday heating (HOLIDAY PROGRAMME)
• Temps / mode
•
Temps / mode hot water
• Instantaneous HW heater (not used)
• Error (FAULTS)
• Diagnostics heat generation
2.1 INFORMATION MENU
In case a fault arises, the first data displayed is the fault code.
To display boiler information, select "
Information
" as indicated in section 2.
Boiler temperature
°C
Boiler flow temperature
Outside temp
°C
Outside temp
Outside temp min
°C
Minimum memorised outside temperature value (with external probe connected)
Outside temp max
°C
Maximum memorised outside temperature value (with external probe connected)
DHW temperature
°C
DHW temperature (value read by the boiler DHW circuit probe)
Manifold temperature
°C
Instantaneous temperature of manifold sensor (with connection to solar plant)
State central heating (1,2,3)
(On/Off)
Heating circuit operating mode (circuits: 1,2,3)
State hot water
Charging
DHW circuit operating mode
State boiler
(On/Off)
Boiler operating mode
Solar state
-
Indicates if sunlight is sufficient (with connection to solar plant)
Telephone customer service
n
xxxxxxxxxx
2.2 TIME AND DATE MENU
To set the time and date, follow the procedure indicated in section 2 and proceed as follows:
• Access the
Set time and date menu
B
1 (Hours / minutes)
B
(the hour flashes)
•
B
to edit the hour
B
to confirm (the minutes flash)
B
to edit
B
to confirm.
•
B
to edit 2 (Day / month) and 3 (Year) performing the same procedure as above.
•
C
to return to the previous menu.
2.3 CHANGE LANGUAGE (Operator unit menu)
To set the language, follow the procedure indicated in section 2 and proceed as follows:
• access the
Operator unit menu
B
and select programme row
20
(Change language);
•
B
to select a language
B
to save.
•
C
to return to the previous menu.