![Baxi Mainfour 24-24F Operating And Installation Instructions Download Page 42](http://html.mh-extra.com/html/baxi/mainfour-24-24f/mainfour-24-24f_operating-and-installation-instructions_2711847042.webp)
42
71.07144.01 - EN
INSTRUCTIONS FOR FITTERS
21. PARAMETERS SETTING
To set the boiler parameters press the (
–
) and (
–
) buttons together for at least 6 seconds. When the function is
active, the letters “F01” will appear on the display, alternating with the value of the parameter shown.
Changing the parameters
• Press the (
+/–
) buttons to scroll through the parameters;
• Press the (
+/–
) buttons to change each parameter value;
• Press the button (
) to save changes, the display shows “MEM”;
• Press the button (
i
) to leave the function without saving, the display shows “
ESC
”;
Description of parameters
Factory settings
24 F
24
F01
Type of boiler
10
= sealed chamber -
20
= atmospheric chamber
10
20
F02
Gas used
00
= NATURAL (METHANE) -
01
= LPG
00 o 01
F03
Hydraulic system
02
F04/ F05
Setting programmable relays 1 and 2 (See SERVICE instructions)
00
= no associated function
00
F06
Maximum temperature setpoint setting (°C)
00
= 76°C
(Switching off the burner at 80°C)
01
= 45°C
00
F07
Configuration DHW priority input
02
F08
Max heating power (0-100%)
100
F09
Max DHW power (0-100%)
100
F10
Min heating power (0-100%)
00
F11
Waiting time in heating before a new ignition
(00-10 minutes) - 00=10 seconds
03
F12
Diagnostics (See SERVICE Instructions)
--
F13
Type of exchanger
00
= 270 mm
01
= 225 mm
01
00
F14
Testing the correct position of the DHW probe
00
= Disable
01
= Enable
01
00
F15
Factory setting
01
00
F16…F18
Manufacture information --- not used
00