4.0 Clearances

7

© Baxi Heating UK Ltd 2013

Fig. 3

Fig. 4

200mm Min

780mm

450mm

5mm Min

5mm Min

450mm Min

For Servicing

Purposes

In Operation

5mm Min

4.1

For your Safety

1. This appliance must have been installed in accordance
with the manufacturer’s instructions and the regulations
in force.

2. Any modification that may interfere with the normal
operation of the appliance without express written
permission from the manufacturer or his agent could
invalidate the appliance warranty. In GB this could also
infringe the Gas Safety (Installation and Use) Regulations.

3. Your boiler must not be operated without the casing
correctly fitted.

4. Do not interfere with any sealed components on this
boiler.

5. Take note of any warning labels on your boiler.

6. Your boiler should have the following minimum
clearances for Safety and Maintenance (Figs. 3 & 4):-

Top

- 200mm 

(300mm for 80/125mm flueing system)

Bottom

- 200mm

Left side - 5mm
Right Side - 5mm
Front

- 5mm (In Operation)
- 450mm (For Servicing)

7. If your boiler is installed in a compartment, do not use
it for storage purposes. Do not obstruct any purpose
provided ventilation openings.

8. Flammable materials must not be stored in close
proximity to your boiler.

9. Avoid skin contact when your boiler is in operation, as
some surfaces may get hot e.g. pipework.

10. Ensure that the flue terminal, outside the house,
does not become damaged or obstructed, particularly
by foliage.

11. It is important that the condensate drain system is
not blocked, modified or damaged in any way as this
would affect the operation of your boiler. Your installer
should have insulated any exposed pipework.

GB

- Heating Industry definition meaning England, Scotland,

Wales, Northern Ireland, Isle of Man and the Channel Isles

200mm Min

(300mm Min if

using 80/125mm

flueing system)

1.5°

Summary of Contents for Main System 24 Eco Elite

Page 1: ...Baxi Heating UK Ltd 2013 User s Guide and Important Warranty Information System Eco Elite Range Please keep these instructions in a safe place If you move house please hand them over to the next occupier ...

Page 2: ...rooks House Coventry Road Warwick CV34 4LL Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Legislation 9 7 0 Notes 10 8 ...

Page 3: ...ator will illuminate when the boiler is in the central heating mode Burner On Indicator The indicator will illuminate when the burner has fired and is heating your central heating or domestic hot water Boiler Output Temperature In either the central heating or domestic hot water position the display will illuminate showing the current boiler temperature in degrees centigrade Central Heating System...

Page 4: ...switched on Reset Is the display lit Display Central Heating Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1 and 2 5 bar If the reading falls below 1 bar repressurise the system as described in section 3 1 Does the display show an error code e g E133 E110 Boiler not working NO NO YES YES YES NO Turn the ON OFF Reset Selec...

Page 5: ...fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible YES NO CONTACTYOUR INSTALLER OR SERVICE ENGINEER YES 12 1 2 3 4 5 6 7 8 9 1 0 11 CH ON CH OFF Typical examples of external timer NO ...

Page 6: ...u are unsure of its position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising should the copper pipe be connected between the two taps Ensure that the nuts on the pipe ends are tightened onto the taps 6 Fully open one of the taps first and then while watching the ...

Page 7: ...inimum clearances for Safety and Maintenance Figs 3 4 Top 200mm 300mm for 80 125mm flueing system Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in close proximity to your boiler 9 ...

Page 8: ... with 33 E50 is shown as E then 50 3 E20 E28 E50 E160 indicate faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 is displayed overheat of the primary water or flue system has occurred Turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regul...

Page 9: ...ciency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Bodies 0086 For GB IE only 6 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the inside back pages of the installation instructions suppli...

Page 10: ...7 0 Notes 10 Baxi Heating UK Ltd 2013 ...

Page 11: ...ning their taps to the right towards the wall Fig 6 3 Call your Installer or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame and do not smoke Open windows and doors in the hazardous area Turn off the gas supply at the meter Warn any other occupants and...

Page 12: ...and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could have the following information to hand 1 Boiler serial number see opposite 2 Boiler make and model number 3 Your installer name and address details 4 Proof of purchase if you do not have the boiler serial number What this warranty covers Free of charge repair or replacement ...

Reviews: