7
b) press the
keys until the display shows P1, referring to the time to be set;
c) press the
keys to set the time; on the display, the letter P will start to flash;
d) press the
key to save and exit the programming function;
3-3 – Setting the maximum central heating temperature
- Press the
key (2-figure 1) to set the central heating water temperature;
- Press the
keys to set the temperature required;
- press either of the
keys (1 or 10 - figure 1) to save and return to the main menu.
N.b – With the outdoor sensor probe connected, the
key (2 - figure 1) can be used to shift the
central heating curve. Press the
keys to decrease or increase the room temperature in
the premises to be heated.
3-4
Setting the maximum domestic hot water temperature
- Press the
key (3-figure 1) to set the maximum domestic hot water temperature;
- Press the
keys to set the temperature required;
- press either of the
keys (1 or 10 - figure 1) to save and return to the main menu.
3-5– Setting the daily program for operation in central heating and domestic hot water modes
3-5.1 Setting the daily times for central heating mode operation
- Press either of the
keys to access the programming function;
a) press these keys until the display shows P11, referring to the program start time;
b) press the
keys to set the time;
- press the
key; the display will show P12, referring to the program end time;
- repeat the operations described in points a and b until the third and last cycle is reached (program
line P16);
- press the
key to save and exit from the programming function.
3-5.2 Setting the daily times for domestic hot water mode operation
- Carry out the operations described in point 3-5.1 for program lines 31 to 36.
3-6 - Setting the minimum central heating temperature
- press either of the
keys to access the programming function;
- press these keys until the display shows P5, referring to the temperature to be set;
- press the
keys to set the temperature required.
This operating mode is enabled when minimum temperature central heating mode
“
”
is activated
or when the daily central heating program does not require heat
.
N.b – With the outdoor sensor probe connected, parameter P5 can be used to set the minimum
room temperature in the premises to be heated.