25
LUNA HT 1.240
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
LUNA HT 280
CO
2
max. heat output
8,7%
±
0,2
10%
±
0,2
CO
2
min. heat output
8,4%
±
0,2
9,5%
±
0,2
Gas nozzle
7,5 mm
7,5 mm
LUNA HT 1.120
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
CO
2
max. heat output
8,7%
±
0,2
10%
±
0,2
CO
2
min. heat output
8,4%
±
0,2
9,5%
±
0,2
Gas nozzle
4,0 mm
4,0 mm
Table 1c
LUNA HT 280
Gas consumption at 15
°
C
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
3.06 m
3
/h
2.25 kg/h
Consumption at min. heat output
0,95 m
3
/h
0.70 kg/h
Table 2b
LUNA HT 1.240
Gas consumption at 15
°
C
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
2.61 m
3
/h
1.92 kg/h
Consumption at min. heat output
0.74 m
3
/h
0.54 kg/h
Table 2d
LUNA HT 1.120
Gas consumption at 15
°
C
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
1.31 m
3
/h
0.96 kg/h
Consumption at min. heat output
0,42 m
3
/h
0,31 kg/h
Table 2e
LUNA HT 330
Gas consumption at 15
°
C
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
3.59 m
3
/h
2.64 kg/h
Consumption at min. heat output
1.06 m
3
/h
0.78 kg/h
Table 2a
LUNA HT 1.280
Gas consumption at 15
°
C
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
1013 mbar
PCI
34.02 MJ/m
3
46.3 MJ/kg
Consumption at max. heat output
3.06 m
3
/h
2.25 kg/h
Consumption at min. heat output
1,06 m
3
/h
0.78 kg/h
Table 2c
Table 1b
LUNA HT 330
G20 - 2H - 20 mbar
G31 - 3P - 37 mbar
LUNA HT 1.280
CO
2
max. heat output
8,7%
±
0,2
10%
±
0,2
CO
2
min. heat output
8,4%
±
0,2
9,8%
±
0,2
Gas nozzle
12,0 mm
12,0 mm
Table 1a