Important Electrical Safety
The heater must
not
be located in front of or under an electrical socket, the socket
must always be accessible in order to disconnect the heater from the electrical supply
for maintenance and cleaning. The electrical socket must not be covered by the
heater.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cut
out, this appliance must
not
be supplied through an external switching device, such
as a timer, or connected to a circuit that is regularly switched on and off by the utility.
Important! The electrical components must be earthed.
The heater is supplied with a 3 pin 13 Amp fused re-wireable plug with 1mm²
3 core cable.
The wires in the cable are coloured in accordance with the following code:-
Live =
Brown
Neutral = Blue
Earth =
Green
/Yellow
The electric supply must be safely routed from the heater to an electrical socket.
If the electric cable is damaged, to avoid a hazard it must be replaced by an
authorised service agent, or similarly qualified person. All external wiring between the
heater and the electrical supply shall comply with current IEE regulations. Extension
leads should not be used.
3. HEATER DIMENSIONS
Page 6
INSTALLER AND OWNER GUIDE
© Baxi Heating U.K. Limited 2009.
Figure 1. Heater dimensions (Heater may differ from that shown)
Dimension A - 1010
Dimension B - 835
Dimension C - 230