8.0 Warranty

12

© Baxi Heating UK Ltd 2015

Annual Service

A service must be completed every 12 months from the

date of installation to maintain your warranty. 

This service must be completed by one of the following:

A Gas Safe registered installer/engineer

Baxi Customer Support; call us 0344 871 1525

Please make sure that your engineer has logged the service

information at the back of the installation and service manual.

You will be asked for your service history on any in-warranty

repair visit.

If you experience a problem with your boiler

For any in or out of warranty repair, Baxi Customer Support is

on hand to help you. Call our award-winning team to arrange 

for one of our nationwide team of Gas Safe registered

engineers to visit.

If your product is in warranty, everything is free of charge, 

subject to our warranty terms and conditions. If it is out of

warranty, we can still help and offer a range of options you can

choose from to suit your needs.

Contact Baxi Customer Support

0344 871 1525

Opening hours

Monday - Friday, 8.00am - 6.00pm

Weekends and Bank Holidays, 8.30am - 2.00pm

Please note calls may be recorded for training and monitoring

purposes.

When contacting Baxi Customer Support, please have the

following information to hand:

Boiler serial number. This can be found on the 

appliance.

Proof of purchase if you do not have the boiler 

serial number.

Please note that for in-warranty repairs, our engineers will ask

to see your service history record, completed Benchmark

Checklist and details of your installer. These can all be found in

the installation and user manual.

Information Label

Summary of Contents for EcoBlue Advance Combi 33

Page 1: ...m Combi User Guide Gas Fired Wall Mounted Condensing Combination Boiler 24 28 33 40 en United Kingdom Please keep these instructions in a safe place If you move house please hand them over to the next...

Page 2: ...work may be liable to criminal prosecution and civil claims for damages 1 0 Quick Reference Guide 3 2 0 Troubleshooting 4 3 0 Repressurising System 6 4 0 Clearances 7 5 0 Care of the Boiler 8 6 0 Leg...

Page 3: ...lluminate when the boiler is in the central heating mode Domestic Hot Water Indicator The indicator will illuminate when hot water is being supplied to a tap or shower Burner On Indicator The indicato...

Page 4: ...on Is the display lit Display Central Heating Indicator Domestic Hot Water Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure between 1...

Page 5: ...ostat if fitted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need hel...

Page 6: ...ts position or cannot identify it consult the installer who fitted the boiler 4 The filling loop consists of two taps and a separate copper pipe with connection fittings 5 Only when repressurising sho...

Page 7: ...labels on your boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Figs 4 5 Top 200mm Bottom 150mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm Fo...

Page 8: ...faulty components You should make a note of the displayed error code and contact your installer or service engineer 4 If E110 or E130 is displayed overheat of the primary water or flue system has occ...

Page 9: ...ciency Regulations 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type te...

Page 10: ...mestic hot water will operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is consid...

Page 11: ...Benchmark Checklist The Benchmark Checklist will be completed by your installer and records that the boiler has been installed and commissioned correctly It can be found at the back of the installati...

Page 12: ...Gas Safe registered engineers to visit If your product is in warranty everything is free of charge subject to our warranty terms and conditions If it is out of warranty we can still help and offer a...

Page 13: ...iciency class A A A A A A A A Rated heat output Prated or Psup kW Space heating Annual energy consumption kWh GJ Water heating Annual energy consumption kWh GJ Seasonal space heating energy efficiency...

Page 14: ...o B e g a k c a p f o s s a l c y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h e c a p s l a n o s a e S R O n i y c n...

Page 15: ...al expression 115 11 Prated whereby Prated is related to the preferential space heater Weighting of boilers 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7...

Page 16: ...m i l c e g a r e v a r e d n u e g a k c a p f o y c n e i c f e y g r e n e g n i t a e h r e t a W y t i c i r t c e l e y r a i l i x u A n o i t u b i r t n o c r a l o S r e t a e h n o i t a n...

Page 17: ...or Service Engineer as soon as possible If you smell gas Do not operate light switches Do not operate any electrical equipment Do not use a telephone in the hazardous area Extinguish any naked flame a...

Page 18: ...12 0 Notes 18 Baxi Heating UK Ltd 2015...

Page 19: ...12 0 Notes 19 Baxi Heating UK Ltd 2015...

Page 20: ...l terms and conditions visit www baxi co uk terms Failure to adhere to terms and conditions will void your manufacturer s warranty Baxi Brooks House Coventry Road Warwick CV34 4LL Please ensure the bo...

Reviews: