29
USER Section (en)
7651556.01 (1-01/16)
154
Delivery/return probe control test
Call the Authorised Service Centre.
160
Fan fault
Call the Authorised Service Centre.
178
Intervention of safety thermostat for excess temperature in
ORZWHPSHUDWXUHV\VWHP
Call the Authorised Service Centre.
270
Overheating exchanger
Call the Authorised Service Centre.
317
162
Call the Authorised Service Centre.
Call the Authorised Service Centre.
321
163
Call the Authorised Service Centre.
Call the Authorised Service Centre.
384
164
3DUDVLWHÀDPHLQWHUQDOHUURU
3UHVVDQGKROGGRZQ
for at least 2 seconds.
385
165
,QSXWYROWDJHWRRORZ
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
431
Exchanger sensor faulty
Call the Authorised Service Centre.
,QWKHHYHQWRIDIDXOWWKHGLVSOD\EDFNOLJKWLQJLQGLFDWHVWKHHUURUFRGHUHVHWDWWHPSWVFDQEHSHUIRUPHGDIWHUZKLFKWKH
ERLOHUVKXWVGRZQ:DLWPLQXWHVEHIRUHDWWHPSWLQJWRUHVHWWKHERLOHUDJDLQ
5. BOILER INFORMATION MENU
3UHVVDQGKROGGRZQ
for at least 1 second, to display the information indicated in the table. Press
to exit.
DESCRIPTION
DESCRIPTION
00
Secondary fault internal code
06
+HDWLQJUHWXUQWHPSHUDWXUH&
01
+HDWLQJVXSSO\WHPSHUDWXUH&
07
)OXHVHQVRUWHPSHUDWXUH&
02
2XWGRRUWHPSHUDWXUH&
08
3ULPDU\H[FKDQJHUWHPSHUDWXUH&
03
Indirect tank DHW temperature (boiler CH only)
09 - 13
Manufacturer information
04
'RPHVWLFKRWZDWHUWHPSHUDWXUH
ERLOHUZLWKSODWHH[FKDQJHU
14
,GHQWL¿FDWLRQ2SHQ7KHUPFRPPXQLFDWLRQ
05
- - -
15 - 18
Manufacturer information
6. SWITCHING OFF THE BOILER
7RWXUQRIIWKHERLOHUGLVFRQQHFWWKHHOHFWULFSRZHUVXSSO\XVLQJWKHWZRSROHVZLWFK,QWKH³2II´RSHUDWLQJPRGH
the boiler stays
RIIEXWWKHHOHFWULFDOFLUFXLWVUHPDLQSRZHUHGDQGWKHDQWLIUHH]HIXQFWLRQUHPDLQVDFWLYH
7. FILLING THE SYSTEM
5HJXODUO\FKHFNWKDWWKHSUHVVXUHGLVSOD\HGRQWKHSUHVVXUHJDXJH
B
LVEDU
ZLWKWKHERLOHUFROG,IWKHSUHVVXUHLVWRRORZWXUQWDS
A
WR¿OOWKHERLOHU¿JXUHWR
side).
7DNH VSHFLDO FDUH ZKHQ ¿OOLQJ WKH KHDWLQJ V\VWHP ,Q SDUWLFXODU RSHQ DQ\
WKHUPRVWDWYDOYHVLQWKHV\VWHPHQVXUHWKHZDWHUHQWHUVVORZO\LQRUGHUWR
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. BAXI declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
7KHERLOHULV¿WWHGZLWKDK\GUDXOLFSUHVVXUHJDXJHZKLFKSUHYHQWVWKHERLOHU
IURPZRUNLQJLIWKHUHLVQRZDWHU
,ISUHVVXUHGURSVRFFXUIUHTXHQWO\KDYHWKHERLOHUFKHFNHGE\WKH$87+25,6('7(&+1,&$/6(59,&(&(175(
8. ROUTINE MAINTENANCE INSTRUCTIONS
7RNHHSWKHERLOHUHI¿FLHQWDQGVDIHKDYHLWFKHFNHGE\WKH$XWKRULVHG6HUYLFH&HQWUHDWWKHHQGRIHYHU\RSHUDWLQJSHULRG
Careful servicing ensures economical operation of the system.
bis
Summary of Contents for DUO-TEC COMPACT+
Page 24: ...7651556 01 1 01 16 112 S E C T I O N A...
Page 30: ...7651556 01 1 01 16 118 S E C T I O N C 722032201 31 5 38 5...
Page 31: ...119 S E C T I O N C 7651556 01 1 01 16 A B C D E F 65 65 65 65 31 5 70 38 5 105 162 5 153 5...
Page 32: ...7651556 01 1 01 16 120 S E C T I O N D 25 mm...
Page 35: ...123 S E C T I O N F 7651556 01 1 01 16...
Page 36: ...7651556 01 1 01 16 124 S E C T I O N G 2 1 D A C G H E F B...
Page 37: ...125 S E C T I O N G 7651556 01 1 01 16...
Page 39: ...127 7651556 01 1 01 16...
Page 40: ...7651556 01 1 01 16 DVVDQR GHO UDSSD 9 7 9LD 7UR HWWL 6HUYL LR FOLHQWL WHO 7HOHID ZZZ ED L LW...