IMPORTANT: Where Low Flow Taps or Fittings
are intended to be used in the DHW system
connected it is strongly recommended that the
DHW flow rate DOES NOT fall below 2.5 l/min.
This will ensure reliable operation of the DHW
function.
Is the Timer ON and
calling for heat ?
Is the Room Thermostat
(if fitted) set high enough ?
12
1
2
3
4
5
6
7
8
9
10
11
Typical
examples of
external timer
Ensure timer is set for
Central Heating ON (see
any instructions supplied
with timer)
NO
YES
YES
NO
15
10
5
20
25
15
10
5
20
25
Turn Room Thermostat
to maximum setting
(typical example shown)
CH ON
CH OFF
bar
0
1
2
3
4
Is the Central Heating
System Pressure
between 1.0 and 2.5 bar ?
If the reading falls below
1.0 bar repressurise the system
as described in Maintenance
NO
Error Code 118 showing
low pressure.
YES