Baxi churchill II 347 Owner'S Manual Download Page 6

OPERATING YOUR FIRE

The Oxysafe flame sensing and flue blockage safety system.

For your safety, this appliance is fitted with a flue blockage safety device that will shut
down the appliance in the event of abnormal flue conditions. 

This device is NOT a

substitute for an independently mounted Carbon Monoxide detector. 

The device will also automatically shut off the gas supply to the fire if the pilot flame
goes out due to lack of oxygen or for any other reason.

If this device starts to repeatedly shut off the gas, get expert advice.

This device incorporates a probe that senses that the heat from the pilot flame is correct.
If this probe is cool, the device will prevent any gas flow unless the control knob is held
down at the ignition position.
If, for any reason, the flames go out when the fire is hot or if the fire is turned off when
hot, always 

wait at least three minutes before attempting to relight

.

To light the fire.

The control is shown in figure 2.
Depress the control knob and turn anticlockwise

towards the 1

position. A spark should be generated

at the pilot while turning. The spark should ignite the
pilot. 

If it does not

, keeping the knob depressed,

continue to turn the knob anticlockwise. A 

second

spark should ignite the pilot. The pilot flame can be
seen through the opening immediately below the right
hand centre radiant (See figure 3). If the pilot does not
light, turn the knob back to ‘OFF’ and try again.

In the unlikely event of failure of the ignition
mechanism the pilot can be lit with a long match or
taper – See the next page.

When the pilot has lit keep the knob depressed for about ten seconds to allow the flame
sensing probe to warm up.

Page 6

OWNER GUIDE

Figure 2.

PLEASE NOTE

When operating your fire for the first time, some vapours may be given off which may
cause a slight odour and could possibly set off any smoke alarms in the immediate
vicinity. These vapours are quite normal with new appliances. They are totally harmless
and will disappear after a few hours use.

Summary of Contents for churchill II 347

Page 1: ...0 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY Manufactured exclusively for British Gas Scottish Gas by Valor Heating For Service Phone 0845 950 0400 Baxi Heating U K Ltd CHURCHILL II Radiant Convector Gas Fire Model 347 G C Number 32 032 62 ...

Page 2: ...r is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company This gas fire must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet Valor Heating Erdington Birmingham B24 9QP w...

Page 3: ...l and local regulations in force Do have the chimney swept prior to installation if it was previously used for solid fuel Do have the fire installed in accordance with the installation instructions Do allow a minimum clearance of 95mm from the top of the appliance fascia to the underside of any shelf whether it is made from combustible or non combustible materials This clearance is necessary to al...

Page 4: ... get advice about the suitability of any wall covering near your fire Soft wall coverings e g embossed vinyl etc which have a raised pattern are easily affected by heat They may therefore scorch or become discoloured when close to a heating appliance Please bear this in mind whenever you are considering redecorating Do provide a minimum clearance of 48mm between the fascia sides and any corner wal...

Page 5: ...ON Has a maximum natural gas input of 5 6kW Gross Has a maximum natural gas output of 4 0kW Has a minimum natural gas input of 1 57kW Gross Has a minimum natural gas output of 1 0kW Page 5 OWNER GUIDE Figure 1 Dimensions and clearances ...

Page 6: ... to relight To light the fire The control is shown in figure 2 Depress the control knob and turn anticlockwise towards the 1 position A spark should be generated at the pilot while turning The spark should ignite the pilot If it does not keeping the knob depressed continue to turn the knob anticlockwise A second spark should ignite the pilot The pilot flame can be seen through the opening immediat...

Page 7: ...t side of the brass handle See figure 3 When the pilot is alight keep the knob depressed for about ten seconds to allow the flame sensing probe to warm up before setting to your preferred heat level For your own convenience have the heater serviced as soon as possible Page 7 OWNER GUIDE Figure 3 Control Knob Position Radiants Condition 2 Centre radiants on low Outer radiants off The right hand cen...

Page 8: ...lacement radiant Ask for part number 5110472 Turn the fire off and allow it to cool before attempting to remove the radiants Remove the dress guard by pressing down the two hooks at the top Tilt the guard forward and lift out Lift the radiant upward to clear the metal retaining bar then pull out bottom first Fit the new radiant by inserting its top under the top lip of the radiant box then swing t...

Page 9: ...ng proper clearance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and their flues wherever situated are checked annually Servicing If...