These clearances must not be
reduced or obstructed in any way.
All clearances are essential in order
to allow correct servicing of the
appliance and access to the fire
control knob.
A shelf may be fitted not less than
76mm (3 in) (100mm (4 in) for C5 &
C5W) above the fire and not more
than 229mm (9 in) in depth.
CLEARANCES AROUND
THE FIRE
The minimum clearance spaces
around the Baxi Bermuda PW5
Deluxe are:
Top:
76mm (3 in)
Side:
89mm (3
1
/
2
in) at right
70mm (2
3
/
4
in) at left
Clearances for C5 & C5W are:
Top:
100mm (4 in)
Sides:
70mm (2
3
/
4
in)
76mm
229mm
SPARE PARTS
Any repairs to the appliance during
the guarantee period, will usually be
the responsibility of the installer after
which, spare parts may be obtained
through an approved Baxi stockists.
The spare parts available and their
relevant part numbers and G.C.
numbers can be found at the back of
the installation and servicing
instructions booklet.
The appliance name, serial number
and G.C. number, which are on the
data badge, should always be
quoted. The data badge is visible on
the left hand fire support leg when the
controls cover panel is removed.
page 6
PW5 Deluxe
C5W
C5
70mm
76mm
89mm
70mm
100mm
70mm
100mm
70mm
70mm