![Baxi Bermuda PW5 C5 Installation And Servicing Instructions Download Page 9](http://html.mh-extra.com/html/baxi/bermuda-pw5-c5/bermuda-pw5-c5_installation-and-servicing-instructions_2711972009.webp)
page 9
Fig. 13 Gas Control Tap/Flame Failure Device
Fig. 14 Radiant Plaque Identification
(Viewed from rear of radiant)
Piezo Igniter
F.F.D./Electro-Magnet Unit
Gas Tap Body
with Plug
NOTICE
Discolouration Of Wall Surfaces
Most heating appliances generate warm air convection currents
and transfer heat to any wall surface against which they are
situated.
Some soft furnishings (such as blown vinyl wallpapers) may not
be suitable for use where they are subjected to temperatures
above normal room levels and the manufacturer's advice should
be sought before using this type of wall covering adjacent to any
heating appliance.
The likelihood of wall staining from convected air currents will be
increased in environments where levels of tobacco smoke or
other contaminants exist.
PW5 Deluxe
C5 & C5W
Gas Tap
This radiant type
MUST
be used on PW5 Deluxe
C5 & C5W appliances.
DO NOT
fit a radiant of
this type to PW5 Deluxe
C5 & C5W appliances.
Spindle
Extension
‘R’ Clip
BAXI SPECIAL
043025
A.S.D.
BAXI SPECIAL
237851
BAXI SPECIAL 043025
BAXI SPECIAL 237851
F.F.D./Electro-Magnet
Unit
PILOT/A.S.D ASSEMBLY
(All Models)
WARNING: The Pilot / A.S.D. assembly should not be
adjusted in any way. The A.S.D. must not be altered
so that it will not operate or be bypassed in any way.
The thermocouple cannot be changed as an
individual component.The complete assembly must
be replaced in the event of one or other component
failure(s). Only use a Genuine Baxi Spare Part.
Release the thermocouple and pilot feed pipe from the
gas tap connection points.
Undo the pilot feed pipe nuts at each end and remove the
pipe.
Undo the thermocouple nut from the tap.
Pull the electrode lead off it’s terminal on the igniter and
withdraw the lead and sleeve through the grommets.
Remove the Pilot / A.S.D. assembly from the appliance.
Fit the new components in reverse order of dismantling.
ELECTRO-MAGNET UNIT
Undo the thermocouple nut from the tap.
Undo the retaining nut.
Withdraw the electro-magnet unit from the tap.
PIEZO UNIT / IGNITER
(PW5 Deluxe)
Pull off the spark electrode.
Twist the retaining tabs to release the piezo unit.
TO FIT A NEW RADIANT PLAQUE
IMPORTANT: Radiant plaques suitable for use with
A.S.D. equipped fires MUST be used.These are Baxi
part no.237851.
Radiant plaques for older models of fire
(part no.043025) MUST NOT be used as they prevent
correct operation of the A.S.D. (Fig. 14).
Remove the dressguard. Lift the radiant up until its base
is clear of the metal lip, pull the base forward over the lip
and lower the radiant out of the frame. Fit the new radiant
by putting the top of the radiant in position, lifting the
radiant over the metal lip and then lowering onto its
support at the back bottom edge of the radiant. Check
that the new radiant lines up with the existing radiants to
ensure that it has been fitted correctly. The lower front
edge should be flush against the radiant support rail.