![Baxi Bermuda PW5 C5 Installation And Servicing Instructions Download Page 10](http://html.mh-extra.com/html/baxi/bermuda-pw5-c5/bermuda-pw5-c5_installation-and-servicing-instructions_2711972010.webp)
page 10
Fault Finding Chart
BAXI BERMUDA C5 / C5W / PW5 DELUXE
Gas Type G20 (Natural Gas)
START
Does the
pilot ignite ?
Is
spark
igniter
working ?
YES
NO
NO
NO
Pilot Flame Size & Spark Gap
3 - 4mm
YES
NO
Clean pilot burner
Change pilot filter
Rectify flue
YES
Replace
piezo igniter
Check electrode
lead & insulation
Is
there a strong
spark at the
electrode ?
Consult
Gas Supplier
Turn on gas
supply
Is
gas supply
turned on ?
Is
supply
pressure correct ?
(20mb working)
NO
YES
NO
YES
YES
NO
Has
new pilot filter
been fitted ?
YES
NO
Is
spark gap
3 to 4mm ?
Adjust spark gap
NO
YES
Is
pilot burner
clean ?
Is flue
blocked causing
A.S.D. to
operate ?
Change pilot
assembly
NO
YES
40mm