Never cover the heater or obstruct the opening at the base of the heater,
this could cause overheating and consequent risk of fire.
Heater Controls
The following switches are located under the controls cover, on the front of the
heater.
Fan
- Use alone for cool air or with heat settings
Heat I
-
Low heat setting
Heat II
-
High heat setting when used together with low
heat setting. Heater will only work if fan switch is on
Flame
Switches flame/fuel effect on/off
Flame Dimmer -
Adjust to set flame intensity
Always disconnect the heater from the electricity supply by removing the 3
pin plug and allowing the heater to cool before undertaking maintenance or
replacing the lamp.
Lamp Replacement
The lamps fitted to this heater are 230V 25W E14 small Edison screw, clear,
candle lamps
Due to the indeterminate life span and ease of replacement they are specifically
excluded from the guarantee.
To replace a lamp.
Remove the small Philips screws securing the fuel basket and put to one side.
Lift up the fuel support
Remove the faulty lamp by screwing the lamp anti -clockwise,
Fit the new lamp
Relocate the fuel support and secure using the Philips screws