with the fan operating and all doors and other openings between the fan and the
appliance open.
If the smoke is drawn into the appliance, continue with the installation. If the test is not
satisfactory
disconnect the appliance and advise the customer of the cause of
failure
.
13.3 Flame supervision and spillage monitoring system.
This pilot unit includes a system that will automatically shut off the gas supply if the
pilot flame goes out or if there is insufficient oxygen due to spillage or poor ventilation.
This monitoring system must not be adjusted, bypassed or put out of operation.
This monitoring system or any of its parts must only be exchanged using Baxi Fires
Division authorised parts.
14. FINAL REVIEW
1.
Visually inspect the appliance. Clean off any marks incurred during installation. The
fire should be ‘off’ and allowed to cool completely before cleaning.
Metal and painted parts.
!
Clean the metal parts with a slightly damp lint free non-abrasive cloth and then dry.
!
Do not use abrasive cleaners as these will scratch the fire surface.
2.
Advise the customer how to operate the appliance. Point out that lighting instruction
details are contained in the owner guide. Explain to the customer that the appliance has
a flame failure & spillage monitoring system. Point out the explanation of this system
shown in the owner guide under “Operating the fire”. Advise that if the fire goes out for
any reason; wait at least three minutes before relighting. Stress that if the monitoring
system repeatedly shuts off the fire, the appliance should be switched off and a
specialist should be consulted.
3.
Advise the customer that they should read their owner guide before operating the fire
and always follow the advice in the section headed “Cleaning your fire”.
4.
Stress that no ceramic fuel effect pieces must be added to the appliance. Warn
that ignoring this advice could cause incomplete clearance of the products of
combustion with consequent health hazards.
5.
Advise the customer that the appliance will operate to its maximum potential if the
flue is primed during the first 20 – 30 minutes of use. To do this, simply turn the control
to its ‘HIGH’ setting.
6.
Recommend that the appliance should be serviced by a competent person at least
annually.
7.
If the appliance is in premises in the United Kingdom occupied by a tenant, point out
that by law a landlord must have any gas appliance, flue and pipework which is situated
Page 24
INSTALLER GUIDE