Page 21
INSTALLER GUIDE
!
If the above test is satisfactory, open all internal connecting doors, hatches, etc. in
the room. Keep all doors and windows that open to the outside of the building closed.
Switch on any extractor fan installed in the same room as the appliance or a connecting
room. Open all doors and other openings between the fan and the appliance. Recheck
for spillage as above. If the smoke is drawn into the appliance, continue with the
installation. If the test is not satisfactory,
disconnect the appliance and advise the
customer of the cause of failure.
Flame Supervision & Spillage Monitoring System
The pilot unit incorporates a system that will automatically shut off the gas supply if the
pilot flame goes out or if there is insufficient oxygen due to spillage or lack of
ventilation.
Check that the system operates properly as follows:
!
Light the appliance. Set at the “HIGH” position and leave for one minute.
!
Turn back to “OFF” to extinguish the pilot.
Note the time when the pilot goes out.
Listen for a snap sound at the gas tap.
Note the time when the sound is heard.
An
electromagnetic valve shutting off the gas supply through the tap causes this sound. The
valve is located in the body of the tap. The valve should operate
within 60 seconds of
the pilot going out.
If the valve does not operate within this time limit do not allow the
appliance to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of operation.
This monitoring system, or any of its parts, must only be exchanged using Baxi
fires division authorised parts.
Final commissioning.
!
Visually inspect the appliance. Clean off any marks incurred during installation.
!
Hand this guide to the customer.
!
Stress that no extra ceramic fuel effect pieces must be added over and above those
supplied with the appliance and that any replacements must only be authorised
spares. Warn that ignoring this advice could cause incomplete clearance of the
products of combustion with consequent health hazards.
!
Advise the customer how to operate the appliance. Point out that lighting instruction
details are contained within the owner guide.
!
Explain that this appliance is fitted with an atmosphere-sensing device, ODS pilot
unit that will automatically shut off the supply of gas to the fire if, for any reason, the
flames go out. It will also shut off the gas supply if the flue is blocked or if there is not
enough ventilation. If this device does operate or if the fire is turned off accidentally or
intentionally, always wait three minutes before attempting to relight.
!
Advise the customer that the fire front and ceramic fuel effect pieces can be cleaned
as described in the owner guide and that the ceramic fuel effect pieces must be replace
as described in the installer and owner guide for the ceramic fuel effect.