background image

altering the room.

Don’t

hang clothing, towels or any other fabrics over the fire.

Don’t

fill in the space behind the fascia.

Don’t

use the fire without the dress guard being in position.

Don’t

attempt to clean or service the fire until it has been switched off and allowed to

cool completely.

Don’t

use the fire with damaged radiants.

APPLIANCE DIMENSIONS

GAS CONSUMPTION

Has a maximum natural gas input of 5.6kW (Gross)
Has a maximum natural gas output of 4.0kW 

Has a minimum natural gas input of 1.57kW (Gross)
Has a minimum natural gas output of 1.0kW 

Page 5

OWNER GUIDE

Figure 1. Dimensions and clearances

Summary of Contents for 347

Page 1: ...to enable the appliance to be operated and maintained satisfactorily However if further information is required our Baxi Fires Division Technical Helpline will be pleased to help Please telephone 08706 061 065 National call rates apply in the United Kingdom In the Republic of Ireland telephone 0044 8706 061 065 Baxi Heating U K Ltd Model 347 Radiant Convector Gas Fire Fitted with one of the follow...

Page 2: ...res Division is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation Baxi Fires Division is a CORGI registered company All our gas fires must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet or floor of combustible ma...

Page 3: ...o improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the excellent performance and features it has to offer SAFETY Do have the fire installed by a competent person In the United Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic o...

Page 4: ...e standards it is a heating appliance and certain parts of its surface will become hot Note The guard supplied with the fire acts as a fireguard conforming to BS1945 1971 and satisfies the Heating Appliance Fireguard Safety Regulations 1991 Do wait three minutes before attempting to relight if the fire is switched off or the flames are extinguished for any reason Your fire is fitted with a safety ...

Page 5: ...o clean or service the fire until it has been switched off and allowed to cool completely Don t use the fire with damaged radiants APPLIANCE DIMENSIONS GAS CONSUMPTION Has a maximum natural gas input of 5 6kW Gross Has a maximum natural gas output of 4 0kW Has a minimum natural gas input of 1 57kW Gross Has a minimum natural gas output of 1 0kW Page 5 OWNER GUIDE Figure 1 Dimensions and clearances...

Page 6: ...t To light the fire Manual ignition The control is shown in figure 2 Depress the control knob and turn anticlockwise towards the 1 IGN position A spark should be generated at the pilot while turning The spark should ignite the pilot If it does not keeping the knob depressed continue to turn the knob anticlockwise A second spark should ignite the pilot The pilot flame can be seen through the openin...

Page 7: ...er The battery can be replaced as shown later in this guide In the unlikely event of failure of the ignition mechanism or where a replacement battery is not available the pilot can be lit with a long match or taper See next page When the pilot has lit keep the control knob depressed for about ten seconds to allow the flame sensing probe to warm up The control control knob can then be set to your p...

Page 8: ...econds to allow the flame sensing probe to warm up before setting to your preferred heat level For your own convenience have the heater serviced as soon as possible CLEANING YOUR FIRE Turn the fire off and allow it to cool before attempting any cleaning Normally the fire will only need dusting The bright metal trims may be cleaned with a damp cloth and dried with a soft duster Obstinate marks can ...

Page 9: ...ss guard in the two holes in the bottom panel apron Push the guard back so that the two spring projections at the top of the guard engage in the slots under the front decorative canopy MAINTENANCE Battery replacement Electronic ignition 1 The battery cover is located at the base of the fire on the right hand side 2 Unscrew the battery cover in an anticlockwise direction 3 Remove the battery and di...

Page 10: ...a Baxi fires division Service engineer or a CORGI registered installer If you require your fire to be serviced please contact Baxi Fires Division Service on 08706 090 081 IMPORTANT To help us quickly help you please try to have the following information available before you contact us Type of fire Model Name Serial Number You will also be asked for the fault problem or request plus your Post Code ...

Page 11: ...o be serviced BAXI FIRES DIVISION SERVICE 08706 090 081 For sales or product information BAXI FIRES DIVISION SALES 08706 061 067 For spares inquiries Spare parts are available nationwide via the interpart stockist network For your local stockist consult Yellow pages under Central Heating CALLERS IN THE REPUBLIC OF IRELAND Call 0044 8706 061 065 Page 11 OWNER GUIDE ...