Chart 2    Speed Dome Functions by Loading Preset Position 

Preset Position Code

 

Function 

51 

Set Point A 

52 

Set Point B

 

53 

Set Guard Location

 

54 

Guard Location Open

 

55 

Guard Location Close

 

61 

Run Pattern   

62 

Stop Pattern 

   

VI. Troubleshooting 

Exception phenomena  Possible reason Relative 

solution 

No display on the screen 
when the power on 

Power supply is not 
connected properly 
 

1.

Check connection of power line   

2.

See if power supply is DC 12V 

No way to control 
designated dome or high 
speed dome 

1.

Protocol is not correct 

2.

Baud rate is not 

correct 

3.

Controlled address is 

not correct 

 

1.

 Check if the keyboard protocol accords with 

that of dome or high-speed dome or not. 

2.

 Check if the baud rate of the keyboard 

accord with that of dome or high-speed 
dome or not. 

3. 

The number in CAM or DATA area can’t 

accord with the object address 

No Beep sound when 
pressing key 

Key-press sound is 
closed 

Start up key-press sound in the keyboard set 

The speed dome is 
controlled not so fast 

The joystick is not set 
correctly 

Reset the joystick value according to 4.2.8 

Other phenomena 

 

Back to manufacturer for maintenance 

 

 

 

Summary of Contents for BVP901

Page 1: ...HE KEYBOARD MENU 6 4 5 1 THE SPEED DOME DECODER SETTING 6 4 5 2 SETTING KEYBOARD PARAMETERS 10 4 5 2 1 ID NUMBER 10 4 5 2 2 BAUD RATE 10 4 5 2 3 SOUND 11 4 5 2 4 MATCHING RESISTANCE 150 11 4 5 2 5 PRO...

Page 2: ...joystick Use this joystick to operate high speed dome It is easy to use with good handling and flexible maneuvering 3 The lock function of the keyboard can prevent unauthorized users to operate the k...

Page 3: ...r needs to input it again 2 ENTER key When you press the ENTER key the inputted number in the Data area to select function or step through ladder functions 3 0 9 Number key Number input 3 1 4 Function...

Page 4: ...Keyboard Instruction Manual 4 The leads of RJ45 socket show as left chart 1 RS 485 D yellow 2 RS 485 D white 7 Power Line POWER1 black 8 Power Line POWER2 red RJ45 Socket Keyboard Connection with Dome...

Page 5: ...oystick is used for controlling the moving direction of dome or high speed dome 1 2 dimentional keyboard joystick Move this joystick to operate dome or high speed dome The running speed of the dome ca...

Page 6: ...n Preset position adjusting is to back to the position you preset input the address of the dome or decoder in the Data area press CAM key to show in the CAM area Input the preset position you would li...

Page 7: ...ve back to the main menu Example Set the running speed of preset position No 1 for Speed Dome 1 as Grade 64 fastest speed dwelling time is 1 second 1 Press the FUN key until LCD displays Press Enter k...

Page 8: ...st pattern cruise group the route is 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 The keyboard displays This dome can set 8 cruise groups with a Max of 16 cruise points 1 128 points at any preset position f...

Page 9: ...a guard location and control the waiting time to the guard location starting and stopping 1 255 seconds before allowing the camera to return to the guard location Press FUN key until LCD displays Pre...

Page 10: ...nts as content in the table 1 below Table 1 Function How To Achieve OSD MENU ENTRY CALL THE PRESET POINT 55 UP CALL THE PRESET POINT 56 DOWN CALL THE PRESET POINT 57 LEFT CALL THE PRESET POINT 58 RIGH...

Page 11: ...ng OFF this will indicate no resistance between RS 485 D and D Press the ENTER key for confirmation The normal status is OFF 4 5 2 5 Protocol Press the FUN key until LCD displays Press 1 key showing V...

Page 12: ...g down F2 OFF key 4 5 5 Auxiliary Switch 1 When the keyboard is under default Main Menu status press FUN until LCD displays as below Set Auxiliary Switch 1 on by pressing down F1 ON key Set Auxiliary...

Page 13: ...o in DATA area monitor No displays in MON area Example Select No 2 Monitor Press CLR key Press Number key 2 Press MON key When completed Monitor 2 is the current monitor 4 5 7 2 Switch one video signa...

Page 14: ...Keyboards only Screw clockwise the middle pillar to its maximum and press NEXT key to finish the relevant maximum data setting The details of operation are in the table below Operation Key Functions S...

Page 15: ...ting OFF as defense withdraw V Common Key Functions 5 1 Default Protocol Operating Key Function Call Adjust preset position Shift Call Set preset position Pan A Limited Site A Pan B Limited Site B Aut...

Page 16: ...tatus 61 Start Cruise 64 Start 360 Scanning Chart 2 Speed Dome Functions by Loading Preset Position Preset Position Code Function 51 Set Point A 52 Set Point B 53 Set Guard Location 54 Guard Location...

Page 17: ...is DC 12V No way to control designated dome or high speed dome 1 Protocol is not correct 2 Baud rate is not correct 3 Controlled address is not correct 1 Check if the keyboard protocol accords with t...

Reviews: