Baur PGK 110 HB Operating Manual Download Page 6

0-6

Contents, 

Continued

Contents

5. Options, Accessories and Ordering Information ..................... 5-1

Overview ...................................................................................... 5-1

Options ....................................................................................... 5-2

Accessories ................................................................................ 5-3

Ordering information .................................................................... 5-5

Summary of Contents for PGK 110 HB

Page 1: ...igh Voltage Testing Sets PGK 70 HB PGK 70 2 5 HB PGK 110 HB PGK 150 HB PGK 260 HB BAUR Prüf und Messtechnik GmbH Raiffeisenstrasse 8 A 6832 Sulz Austria Tel 43 55 22 49 41 0 Fax 43 55 22 49 4 13 e mail headoffice baur at internet http www baur at ...

Page 2: ...0 2 ...

Page 3: ...ding Copyright by BAUR This manual contains all information necessary for the correct handling and use of the high voltage testing set PGK 70 HB PGK 70 2 5 HB PGK 110 HB PGK 150 HB und PGK 260 HB Before using the surge voltage generator please read carfully this Operating Instruction Preface If you have any question please contact directly BAUR Prüf und Messtechnik GmbH Raiffeisenstrasse 8 A 6832 ...

Page 4: ...s possible all parts that become faulty or useless as the demonstrable results of poor material faulty design or defective execution We bear the costs for repairs and replaced parts exclusive transportation of the goods packing and insurance The 12 month warranty time starts with delivery We shall bear the costs of any faulty parts requiring replacement but not the costs of transport to us an back...

Page 5: ...s 1 4 Technical data 1 5 PGK Load curves 1 6 2 Packing and Shipping 2 1 Damage during transport 2 1 3 Placing into operation 3 1 Overview 3 1 Connect to earth 3 2 Switch on 3 2 Switch off 3 4 EMERGENCY OFF 3 4 Change operating mode 3 5 4 Servicing Maintenance 4 1 Overview 4 1 General 4 2 Fuse 4 2 Contents ...

Page 6: ...0 6 Contents Continued Contents 5 Options Accessories and Ordering Information 5 1 Overview 5 1 Options 5 2 Accessories 5 3 Ordering information 5 5 ...

Page 7: ... Display and operating elements 1 4 Technical data 1 5 PGK Load curves 1 6 1 Product Information Overview This section contains all necessary information about the High Voltage Testing Sets PGK HB This section contains the following subjects General view PGK 70 HB ...

Page 8: ...rading ring The PGK HB instruments are designed as two part High Voltage Testing Sets Operating unit with all indicating operating elements with power supply and safety devices High Voltage unit as oil filled housing with High Voltage trans former with the choice of a rectifier bar for half wave rectification or a resistance bar as a damping resistor Design Depending on the load by the test object...

Page 9: ...ansformer Must be considered during measurements on test objects The kV meter is connected to a tapping of the H V winding and is current compensated The compensation is balancing the voltage drop at the internal resistance of the test instrument D C operation The kV meter shows the peak value of the output voltage If the self capacitance of the test object is very low it is possible that the insu...

Page 10: ...switch with thermal and magnetic tripping 6 Voltmeter for display of output voltage in kV 7 Amperemeter for display of output current in mA 8 Measuring range switch for amperemeter 9 Selector switch for operating mode 10 Measuring range switch for voltmeter 11 Variable transformer for setting the output voltage 12 Lockabel Emergency off momentary contact switch 13 Indicator lamp green 14 Indicator...

Page 11: ...78 94 126 110 160 185 260 kV Output voltage ACeff DC at nominal working point 47 66 55 62 90 108 110 137 185 250 kV Max output current ACeff DC at short circuit 20 12 117 84 30 17 23 20 20 20 mA Accuracy of kV meter 2 5 2 5 2 5 2 5 2 5 Accuracy of mA meter 2 5 2 5 2 5 2 5 2 5 Dimensions of operating unit 502 x 502x 502 x 502 x 502 x housing W x H x D 242 x 290 242 x 290 242 x 290 242 x 290 242 x 2...

Page 12: ...1 6 1 Product Information PGK output load curves ...

Page 13: ...1 7 1 Product Information ...

Page 14: ...1 8 1 Product Information Load curve PGK 110 HB AC 1 8 Load curve PGK 110 HB DC 0 10 20 30 40 50 60 70 80 90 100 0 5 10 15 20 25 30 35 I kV U kV 0 20 40 60 80 100 120 140 0 5 10 15 20 I mA U kV mA ...

Page 15: ...oad curve PGK 150 HB AC LLoad curve PGK 150 HB DC 0 10 20 30 40 50 60 70 80 90 100 110 120 130 0 3 6 9 12 15 18 21 24 I mA U kV 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 0 2 4 6 8 10 12 14 16 18 20 22 I mA U kV ...

Page 16: ...15 20 25 I mA U kv Attention maximum admissible output voltage 190 kV rms Load curve PGK 260 HB DC Load curve PGK 260 HB AC 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 0 2 4 6 8 10 12 14 16 18 20 22 I mA U kV Attention maximum admissible output voltage 260 kV ...

Page 17: ...hipping containers on wooden pallets If the instruments are not used immediately always keep in the closed carton or shipping container and store in dry rooms The H V unit may only be transported and operated vertically It is important that the tube is not bended so when packing in shipping containers it may not be used as a support For securing the H V unit mounting holes are in the base plate Ad...

Page 18: ...2 Packing and Shipping Notes 2 2 ...

Page 19: ...h off 3 4 EMERGENCY OFF 3 4 Change operating mode 3 5 3 Placing into Operation Overview In this section you will find all necessary information to put the High Voltage Testing Sets PGK 70 HB PGK 70 2 5 HB PGK 110 HB PGK 150 HB and PGK 260 HB into operation This section contains the following subjects ...

Page 20: ...o applying the test voltage to the test object Insert rectification resp resistor bar option with PGK 260 HB according to the desired operating mode Connect operating unit and H V unit Install H V connection to the test object Connect instrument to mains according to specifications on type plate Turn variable transformer 11 to the left position Set measuring range selector switch for the kV meter ...

Page 21: ...nto operating condition READY TO SWITCH ON only if the EMERGENCY OFF pushbutton switch is not depressed the overcurrent protection switch 5 has not been tripped The instrument is in operating condition READY TO SWITCH ON the green indicator lamp 13 is out the red indicator lamp 14 is illuminated Press pushbutton High Voltage On I 3 The high voltage transformer will be connected to the mains voltag...

Page 22: ...ator lamp 14 is out the green indicator lamp 13 is illuminated The instrument can only be placed in the operating condition READY TO SWITCH ON by pressing the pushbutton switch 2 Ready to switch on if the EMERGENCY OFF momentary contact switch has been unlocked with the key By pressing the EMERGENCY OFF momentary contact switch and taking out the key unauthorized use of the instrument can be preve...

Page 23: ...red polarity The resistor bar is marked on one end with front end of screw plug The rectifier bar is marked on the ends with and If negative H V should be want the mark must be on top at the H V output Clean bar with dry or slightly dampened in petroleum ether and fuzz free clothes Slowly insert cleaned bar into the tube When operating mode is changed very frequently it must be observed that alway...

Page 24: ...3 Placing into Operation 3 6 Notes ...

Page 25: ...n this section you will find all necessary information regarding servicing and maintenance of the High Voltage Testing Sets PGK 70 HB PGK 70 2 5 HB PGK 110 HB PGK 150 HB and PGK 260 HB This section contains the following subjects Subject Page General 4 2 Fuse 4 2 ...

Page 26: ...il lamps light up Oil for refilling around the rectifier or resistor bar is available from BAUR 0 8lt insulation oil Technol US 4000 ID no 471 716 Fuse Designation Value Dimension Ident No Remarks F1 F2 0 16 AT Ø 5 x 20 mm 563 005 Mains transformer primary F3 F4 2 AF Ø 5 x 20 mm 563 020 12V control F5 F6 3 15 AT Ø 5 x 20 mm 563 021 Discharge unit option S4 F10 16 AT Mains switch F11 PGK 70 HB 2 A ...

Page 27: ...n regarding options and accessories available for the High Voltage Testing Sets PGK 70 HB PGK 70 2 5 HB PGK 110 HB PGK 150 HB and PGK 260 HB 5 Options Accessories and Ordering Information Overview This section contains the following subjects Subject Page Options 5 2 Accessories 5 3 Ordering information 5 5 ...

Page 28: ...ition is monitored When the instrument is back in operating condition READY FOR OPERATION a short circuit bar is moved to the corona protection hood by a spring A discharge resistor is responsible for discharging the connected capacitances As additional accessory a folding tripod can be supplied It makes operation of the instrument easier if no working table is available Working height is approx 9...

Page 29: ...strument against transient voltages and high currents in case of short circuit during A C operation Rectifier bar option with PGK 260 PGK unit 70 HB 70 2 5 HB 110 HB 150 HB 260 HB Resistance value 33 kΩ 3 kΩ 30 kΩ 99 kΩ 132 kΩ Tolerance 10 10 10 10 10 Is used for loosening the threaded insert when changing the operating mode of the instrument It is a cylindrical spanner which is inserted into the ...

Page 30: ... safety plug 554 016 Powercord with US plug 554 017 Powercord with free cable end Connecting lead between H V and operating unit is 5 m long and is connected with lockable connectors on both sides A High Voltage insulated wire with a length of 5 m and a cross section of 1 5 mm is used as High Voltage connecting lead The instrument side is equipped with a cable lug with hole diam 8 5 mm with PGK 70...

Page 31: ...SetPGK70HBwithaccessories 411 010 411 110 411 210 Operatingunit 470 006 470 007 470 008 HighVoltageunit 470 042 470 042 470 042 DischargebarES7012kWs 411 510 411 510 411 510 Mainsconnection 554 015 554 016 554 017 ConnectingcableH V Operatingunit 5m 471 933 471 933 471 933 Earthlead 3m 460 462 460 462 460 462 HighVoltageconnection 2 5mwithalligatorclip 460 476 460 476 460 476 Spannerforreplacing r...

Page 32: ...ion PGK 110 HB Items supplied Ordering information PGK 150 HB 220 230V 110 120V 240V HighVoltageTestSetPGK150HBwithaccessories 411 013 411 113 411 213 Operatingunit 470 016 470 017 470 018 HighVoltageunit 470 044 470 044 470 044 DischargebarES150 411 512 411 512 411 512 Mainsconnection 554 015 554 016 554 017 ConnectioncableH V Operatingunit 5m 471 933 471 933 471 933 Earthlead 3m 460 462 460 462 ...

Page 33: ...ection 2 5mwithalligatorclip 460 477 460 477 460 477 Spannerforreplacing rectifier resistorbar 460 459 460 459 460 459 Rectifierbar builtin 470 060 470 060 470 060 ResistorbarforA C operation 470 059 MovingframeHighVoltageunit 470 584 Foldingtripodfor19 units workingheightapprox 90cm 411 536 AutomaticdischargedeviceEM260 470 627 EmergencyOff unitwithsignallamps 25m 471 219 EmergencyOff unitwithsig...

Page 34: ...5 Options Accessories and Ordering Information 5 8 Notes ...