TAM00720
9
DSM1
10/2015
Three-phase-synchronous motor
English
Attention:
The mentioned protection classes only are reached if the connectors were mounted com-
pletely (the main and the control connections).
Cooling process (EN 60034-6)
IC 410 Standard: Self-surface cooling; cooling without
using a fan, but by natural ventilation
Electrical connections (see chapter 7).
Receptacle orientation
Standard: Radial outgoing
Optional: Others on request
Main connection
Receptacle 8-pole
Standard: U, V, W +temperature sensor
Optional:
Brake
Control connection
12-pole
Standard: Resolver
Optional:
Others on request
Thermal motor protechtion (EN60034-11) Temperature sensor KTY84/130 in the stator winding
Barrier (EN 60034-1)
Temperature class F (
∆θ
= 105 K)
Ambient temperature
0°C... + 40°C
Installation altitude (EN 60034-1)
≤
1.000 m above sea level (standard)
Bearing
Deep-groove ball bearing with permanent lubrication
Calculated service life of bearing
L
H10
20.000 h (approximate value)
Service life of shaft seal
see chapter 5.2 Maintenance
Vibration quantity step (EN 60034-14)
Standard:
A
Nonstandard: B
Shakeproof (EN 60068-2-6)
radial:
3 g
(10 Hz to 100 Hz)
axial: 1 g (10 Hz to 100 Hz), with brake 0,5 g
Concentricity shaft end (DIN 42955)
Standard:
N
Nonstandard:
R (reduced)
Holding brake
Optional
Actual speed value encoder
Nonstandard:
2-pole resolver
(high-grade version on request)
Optional: Absolute encoder with hiperface interface
Optional: Absolute encoder with Endat interface
Attention!
If the delivered electric motor doesn’t correspond to the standard version accordant to the technical list
or if special contractual terms were agreed upon, technical deviations referring to this commissioning
and maintenance guide can occur. Please, ask for the corresponding technical additions.