Example:
1.First set
DO 1 source Pxxx
to 13,
DO 1 bit pattern
to
0001,
and
DO 1 bit selection
to
0003.
→
if bit no. 1 and bit no. 2 of parameter P013 result in „1“, the output 1 is switched to high.
Parameter overview
Parameter description
P383
DO
1 source Pxxx
This parameter indicates the parameter number of the source parameter for outputs 1, 2 or 3.
P384
DO
1 bit selection
The bits to be compared are selected in the source parameter.
P385
DO
1 bit pattern
Bit pattern which is compared to the source parameter bit pattern.
P392
DO
state
This parameter shows the state of the function module.
Parameter
Name
Range
min. ... max.
Unit
Display
only
P383
DO
1 source Pxxx
0 ... 700
P384
DO
1 bit selection
0000 ... FFFF
P385
DO
1 bit pattern
0000 ... FFFF
P392
DO
state
0000 ... FFFF
!
Bit no.
Meaning
0
1: output 1completely programmed
1
1: output 2 completely programmed
2
1: output 3 completely programmed
3 ... 7
reserved
8
actual state output 1 (X26:21)
9
actual state output 2 (X26:22)
10
actual state output 3 (X26:23)
11 ... 15
reserved
Summary of Contents for BUS 6 VC
Page 1: ...E 5 03047 01 Manual V Controller BUS 6 VC Specification Digital Control BUC ...
Page 4: ...Dokument Nr Document No 5 04058 01 Baumüller Nürnberg GmbH ...
Page 8: ...6 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 14: ...Technical Data 12 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 92: ...Parameter 90 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 108: ...Appendix 106 V Controller BUS 6 VC 5 03047 01 Baumüller Nürnberg Electronic GmbH Co KG ...
Page 109: ......