3.4.17 Synchronization
3.4.17.1 Parameter overview
Functional block:
FbSynchronisation[156]
3.4.17.2 Description of the Parameters
156.1
Mode
Switch on or switch off synchronization to fieldbus signal.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
Axis
-ind
epen
den
t
156.1
Mode
UINT
0
1
0
1:1
X
X
156.2
Status
UINT
0
0xFFFF
0
1:1
X
X
156.3
Sync tolerance
UINT
0
0x1FFF
1000
µs
1000:20
X
X
156.4
Sync offset
DINT
-2147483648
2147483647
0
µs
1000:20
X
X
156.5
Fieldbus cycle
UDINT
0
4294967295
0
µs
1000:20 X
X
156.6
Fieldbus jitter
DINT
-2147483648
2147483647
0
µs
1000:20 X
X
156.7
Sync error
DINT
-2147483648
2147483647
0
µs
1000:20 X
X
156.8
Max. jitter positive
DINT
0
262144
0
µs
1000:20
X
156.9
Max. jitter negative
DINT
-262144
0
0
µs
1000:20
X
156.15
Time fieldbus write
access
DINT
-500000
500000
0
µs
1000:20 X
X
156.16
Time DSP read access
DINT
-500000
500000
0
µs
1000:20 X
X
156.17
Time DSP write access
DINT
-500000
500000
0
µs
1000:20 X
X
156.18
Time fieldbus read
access
DINT
-500000
500000
0
µs
1000:20 X
X
156.19
Time fieldbus read to
DSP read
DINT
-500000
500000
0
µs
1000:20 X
X
Bit
Meaning
0
0: Synchronization is switched off
1: Synchronization is switched on
1
0: Automatic adjustment of the Sync offset