Technical Data
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
63
3
3.4
Electrical data basic units
3.4.1
Electrical data of the universal units
3.4.1.1 Electrical data BM441X universal units
BM441
2-
XTX
BM441
3-
XTX
BM441
4-
STX
9)
BM441
4-
CTX
8)9)
Rated input power
1)
1.9 kVA
3.3 kVA
5.1 kVA
6.9 kVA
Rated input rated current
1)
(I
eff
)
2.8 A
4.8 A
7.3 A
10.0 A
Total harmonic distortion input current
1)
(THD
I
)
119 %
110 %
109 %
113 %
Current input max. (I
eff
)
5.2 A
9.0 A
20.0 A
20.0 A
DC link rated voltage
1 )
(U
DC
)
540 V
DC
DC link capacity (internal)
110
F
240
F
330
F
330
F
DC link discharge time
(internal DC link capacity)
80 s
175 s
240 s
240 s
DC link capacity (external), permitted
see
Period between two power up processes
12)
at least 60 s
Output voltage
1)2)
(U
AC
)
3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
12)
0 Hz to 450 Hz
Rated output current
1)4)5)6)13)
(I
AC
) at 4 kHz
3)
2.5 A
4.5 A
5.5 A
7.5 A
Rated output current
1)4)5)6)13)
(I
AC
) at 8 kHz
3)
2.5 A
4.5 A
5.0 A
5.0 A
Output peak current
1)4)5)7)13)
(I
AC
) at 4 kHz
3)
5.0 A
9.0 A
20.0 A
20.0 A
Output peak current
1)4)5)7)13)
(I
AC
) at 8 kHz
3)
5.0 A
9.0 A
12.0 A
12.0 A
Max. peak current period
7)
60 s
1 s
Power input DC link terminals
10)
max. 2.0 kW
max. 3.0 kW max. 4.3 kW
Brake resistor current, permitted (Î)
max. 5.9 A
max. 12.0 A
Brake resistor external
130
65
Brake resistor threshold (Û)
780 V
Brake resistor peak power
4.5 kW
5.0 kW
9.4 kW
9.4 kW
Permitted continuous power
brake resistor external
1.0 kW
1.5 kW
3.0 kW
3.0 kW
Power loss referring to power input
33 W
60 W
80 W
102 W
Power input referring to control voltage
max. 60 W
Current of the integrated brake connection
max. 0.5 A
max. 1.0 A
Summary of Contents for b maxx BM4400