Wiring diagrams
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
194
7.10
Notes on the usage of an OSSD test pulse see
C.4 Requirements on an OSSD test
Notes on the usage of an OSSD test pulse see
C.4 Requirements on an OSSD test
7.10.4 Requirements for the screwing
X101
(SELV/PELV)
Max. cross-section
of connection
Connection
technology
Load capacity
Brake
BM4412
BM4413
BM442X
1.5 mm
2
Plug-in contact
X101-1 bis X101-4:
min.
0.1
A, max.
0.5
A
BM4414
BM443X
BM463X
1.5 mm
2
Plug-in contact
X101-1 bis X101-4:
min.
0.1
A, max.
1.0
A
BM444X
BM464X
1.5 mm
2
Plug-in contact
X101-1 bis X101-4:
min.
0.1
A, max.
4.0
A
BM445X
BM446X
BM447X
BM465X
BM466X
BM47XX
1.5 mm
2
Plug-in contact
X101-1 bis X101-4:
min.
0.1
A, max.
8.0
A
if you consider UL508C:
max.
4.0
A
X102 (option)
Safety relay
Max. cross-section
of connection
Connection
technology
Load capacity /
voltage level
(SELV/PELV)
1.5 mm
2
Plug-in contact
see
X103 (0ption)
Safety relay
Max. cross-section
of connection
Connection
technology
Load capacity /
voltage level
(SELV/PELV)
1.5 mm
2
Plug-in contact
see
NOTE!
Follow the mentioned torques in
page 189 to ensure an adequate conductivity.
Summary of Contents for b maxx BM4400