![Baumuller b maXX BM2500 Operating Manual Download Page 625](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400625.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
625
4
The displayed value is in format 16 bits increments/revolution per ms².
136.11
Effective interpolation interval
Parameter to display the effective interpolation interval:
Interpolation interval = Factor * Fieldbus cycle time
The factor can be adjusted in Parameter
Mode in Bits 12 and 13.
The fieldbus cycle time is adjusted in Parameter
.
136.12
Output angle set value
This parameter shows the calculated set value angle after offset addition and is updated
during the cycle of the set value interface.
The displayed value is in format 32 bit angle.
136.13
Smoothing time position set value
In this parameter the time constant of the PT
1
filter for smoothing the transferred position
set value is set in the operating mode "Position control with synchronous set of setpoints".
The PT
1
element is calculated after Parameter
Speed limit, i.e. the already in-
terpolated and limited position set value delta is smoothed.
The value 0 indicates no smoothing.
136.14
Speed set value unlimited
This parameter shows the current speed set value after speed offset addition (
)
but before speed limit by parameter
The displayed value is in format 32 bits increments/revolution per ms.
NOTE!
m
With the transfer in the "operation enable" state the change of smoothing time is
activated, i.e. not until pulse inhibit and a re-enabling.
m
the output set value reaches the input set val-
ue delayed, due to the PT
1
element. The implemented PT
1
algorithm prevents a
constant deviation at a constant input set value. However, another time delay is
provided by the clearing mechanism until the input value is reached. A completed
transient is visible at bit 4 speed set value = 0 of parameter