Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
252
4.4
131.14
Software IP address
Using Slave Options, it is possible to define whether the IP address is determined from
this parameter or from the DIP switches.
131.15
Actual IP address
Display of the current IP address (depends on
)
131.16
Gateway
Gateway IP address
131.17
Subnet mask
Subnet mask associated with the IP address.
Recommended value: 255.255.0.0
131.18
Fieldbus cycle time
Setting for the Fieldbus cycle time in ns.
Besides the
division ratio of fieldbus task its value determines the
field-
bus task cycle is determined (=cycle of the set value generator for cyclical set values).
131.19
Slave error code
Error code for the EtherCAT slave.
NOTE!
A parameter change is permitted at a inhibited state and in the fieldbus state INIT
(
slave info bit 0 and 1), only.