Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
535
4
4.8.1.4 Description of the Parameters
121.1
Positioning general mode
Remark:
m
Bit 0: Software limit switch monitoring
Bit 0 is used to switch on monitoring for software limit switches.
Bit 0 = 0: Monitoring of software limit switches is deactivated.
121.15
Modulo revolutions
UDINT
0
0x7FFFFFFF
1
1:1
X
121.16
Rotation position resolution
UDINT
0
0x7FFFFFFF
3600000
1:1
X
121.17
Modulo position actual value UDINT
0
0xFFFFFFFF 0
1:1
X
121.18
Status
DWORD 0x0
0xFFFFFFFF 0x0
1:1
X
121.19
Speed actual value load
basis
FLOAT
-2147483648
2147483647
0
Grad/s 1:1
X
121.20
Coarse position window
UDINT
0
0xFFFFFFFF 0x2000
Inc
1:1
X
121.21
Command positive stop drive WORD
0x0
0x1
0x0
1:1
X
121.22
Status positive stop drive
WORD
0x0
0xFFFF
0x0
1:1
X
121.23
Mode positive stop drive
WORD
0
0xFFFF
0
1:1
X
121.24
Positive stop position
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
121.25
Monitoring window positive
stop drive
UDINT
0x0
0x7FFFFFFF
0x1000
Inc
1:1
X
121.26
Offset modulo position actual
value
DINT
0x80000000
0x7FFFFFFF
0x0
1:1
X
121.27
Command value mode
WORD
0
0xFFFF
0x0002
1:1
X
Bit
Meaning
0
1: Software limit switch monitoring ON
1
1: Hardware limit switch monitoring ON
3 … 2
Reserved
4
1: Calculation of Modulo position actual value ON
5
1: The revolution overflows of the encoder in parameter
are
ignored at initialization of Modulo position actual value.
6
1: The position actual value (
) is set to the value of the calculated
modulo position actual value (
); the setting is relevant at an
active calculation of the modulo position actual value!
7
1: If bit 5 = 1 and bit 7 = 1, the available revolutions in the position actual
value above
encoder number of revolutions are not used to ini-
tialize the modulo position actual value (
).
15 ... 8
Reserved