Accessories and spare parts
Instruction handbook
b maXX
5000
Document No.: 5.09021.16
253
11
11.1.9.1 Connecting cable for Resolver
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC 1x2x0.25-Li9Y 2x2x0,25-Li9Y C11Y 1x2x0.34GN.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 12-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 108:
Connecting cable for resolver
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not operable and could lead to de-
fects, both in the encoder module and the encoder!