3.3.5
Required environmental conditions
1)
For an operation in an environment of category C2 according to IEC 61800-3:2012 additional measures may be required.
In this case the system manufacturer/operator must provide evidence, that these additional measures are effective and that the limit
values specified in IEC 61800-3 of category C2 are complied with.
2)
See correction factors at modified environment conditions,
3)
See correction factors at modified environment conditions,
BM3000
BM3200, BM3300
Transportation temperature range
-25 °C to +70 °C
Transportation climate classification
EN 60721-3-2
2 K 3
Storage temperature range
-25 °C to +55 °C
Storage climate classification
EN 60721-3-1
1 K 4
Operation environment
Industrial supply network
1)
Operation temperature range
min. 5 °C to max. 40 °C
min. 5 °C to max. 55 °C
(with derating above 40 °C)
2)
Operation climate classification
EN 60721-3-3
3 K 3
Installation altitude
up to 2000 m altitude
(with derating above 1000 m)
3)
Humidity (operation)
EN 60721-3-3
relative humidity: 5 % to 85 % non-condensing
and
absolute humidity: 1 g/m
3
to 25 g/m
3
Ionizing and non-ionizing radiation
< measurable range
Vibration, shock and repetitive shock
EN 61800-5-1, section 5.2.6.4 vibration test
max. 0.5 g operating (1 g tested)
Pollution degree
EN 61800-5-1, table 6, tab. 2
2
NOTICE!
Normally, only non-conductive pollution occurs. Any conductive pollution, if for a
short-term or permanently, is forbidden and can cause the destruction of the device.
The customer is responsible for destructions, which are caused by conductive mate-
rials.