8
02/11/2010
Germany: +49 (0)2361 / 30 231 – 0; Switzerland: +41 (0)44 / 954 80 7 - 0
1
2
3
5.3 Control
Main equipment cabinet
One part of the control elements for the machine process is located in the lower section of the cleaning
machine. The fuses, motor protection, PLC controller, protection for motors, clamps and safety relays
are here.
5.4 Electric Field Sensors
All the machine’s sensors such as the limit switch, buttons and safety relays, for example, are connected to the
PLC controller. The switching statuses of the sensors are shown on the sensors or the PLC.
5.5 Operator’s Console
The machine’s operator’s console fulfils the following functions:
1) Button/lamp combination
The machine is switched on and off with this.
Among other things, the integrated signal light (white field) indicates the
following:
Solid light – machine is running without any problems
Flashing – Machine malfunction
The lamp flashes if the emergency stop relay has been triggered and the
“On” switch is pressed at the same time.
2) Emergency stop reset switch
The emergency stop reset switch is used to acknowledge the emergency off
relay after it has been triggered.
3) Emergency stop switch
The emergency stop switch can be used to stop dangerous movements in
the event of danger.
Please note: The cylinder may still be under pressure even if the emergency
stop button has been pressed. The emergency stop switch is not a repair
switch!!!
5.6 Cleaning Chamber
The filter chamber consists of a closed stainless steel container (1) that
forms a tight seal with the protective doors.
The slewing ring (2) with the extraction funnel (3) are located in the base
area.
The chamber and the slewing ring must be cleaned occasionally. This
can be done with the industrial vacuum cleaner.
Please note: A protective mask must be worn while cleaning.
If cleaning cloths are used, then they must be disposed of properly after
cleaning.
2
3
1