TP10494A
PAGE 31
Start sheet (press
“SHEET START”
).
Notes:
If the wrong
“FOLD TYPE”
button is pressed, you
can either press the
“RESET”
button instead of the
“ENTER”
button or press the correct
“FOLD TYPE”
button, then the
“ENTER”
button.
After every new set up the machine speed will always
be reset to 60%.
The fold type status LED, when lit constantly,
indicates that the fold plates are set for this type of fold.
Any time the folder is running and a change is made
that causes the fold plate stops to move; the main drive will
stop.
11.0 COUNTER OPERATION
During normal operation, the display should show
the total count (maximum count 9,999,999), current batch
size (3 digits)and the total number of completed batches (5
digits). This display is known as the count screen.
11.1 Resetting the total count
To reset the total count press the
“RESET”
button,
then press the
“COUNT”
button. This also resets the batch
counter, (# of batches & # in the batch).
11.2 Programming the batch counter
Program the batch counter by pressing the
“SET
BATCH”
button. The
set batch
screen will be displayed.
TOTAL COUNT #######
BATCH ### #####
RESET
TOTAL COUNT #######
BATCH ### #####
SET BATCH
### #.#