![Baumfolder FLEXIFOLD 1st STATION Installation & Operation Manual Download Page 25](http://html.mh-extra.com/html/baumfolder/flexifold-1st-station/flexifold-1st-station_installation-and-operation-manual_2711288025.webp)
TP10494A
PAGE 25
Figure 6.1-1
Gap Knob
6.2 Feed Table Adjustment
On the paper feed table there are two guides which
keep the stack of paper properly aligned for feeding into the
folder. Adjust these guides to correspond with the different
widths of paper being fed.
(See Figure 6.2-1)
To adjust the paper feed guides, loosen the two side
guide locking knobs on each guide. Slide the guides from
side to side until the inside edge of each guide is aligned
with the number corresponding to the width of the paper
being folded.
Example: For a 10cm wide sheet, move the side
guides until the inside edges align with the “10” on the feed
table.
An additional check is to lay a sheet of paper on the
feeder, close to but not touching the side guides. Push the
sheet down into the nip of the fold rolls. Then align the
guide by loosening the adjusting knobs and aligning the
guide so that it is parallel to the edge of the paper. When
one side is square, the other side can be moved into position.
Tighten the locking knobs to secure the paper guides
in position.
When you load the actual job, you may have to move
these guides slightly to take care of variations in sheet size.
To feed properly, the paper must slide freely between these
guides.
Figure 6.2-1
Side Guide Lock-
ing Knobs
Side Guide
Adjustment Knob
Side Guides
Skew Adjustment
6.0 FEED TABLE SETUP
(If Applicable)
6.1 Gap Adjustment
With the machine running, insert two sheets of
paper between the tab and the sucker wheel. Turn the
gap knob counterclockwise until there is a slight drag on
the paper. Remove the paper. The correct gap is now set.
(See Figure 6.1-1)
6.3 Air Blow Adjustment
Turn the air blow adjustment on the vacuum/air
control panel fully clockwise to the (-) position.
(See Figure
6.3-1)
Adjust the air blow to float the sheet stack using the
air blow adjustment, this is to separate the bottom 4 or 5
sheets. The feeder valve knob may be used to balance the air
between the left and right side of the feed table.(See Figure
6.3-2).
Turn the knob to the right to obtain more blow on the
right side and front of the feed table. Turn the knob to the