42
Configurable
9.6.1.2
Outputs
With this feature, Baumer offers the possibility of wiring the output connectors to internal
signals, which are controlled on the software side.
Hereby on
VisiLine
®
cameras, the output connector can be wired to one of provided inter-
nal signal: "Off", "ExposureActive", "Line 0", "Timer 1 … 3", "ReadoutActive", "User0 …
2", "TriggerReady", "TriggerOverlapped", "TriggerSkipped", "Sequencer Output 0 ... 2".
Beside this, the output can be disabled.
(Output) Line 1
state high
state low
(Output) Line 2
state high
state low
(Output) Line 3
state high
state low
IO Matrix
state selection
(inverter)
signal selection
(software side)
Line0 (Input)
Line1 (Input)
Line2 (Input)
Off
TriggerReady
TriggerOverlapped
TriggerSkipped
ExposureActive
ReadoutActive
UserOutput0
UserOutput1
UserOutput2
Timer1Active
Timer2Active
Timer3Active
SequencerOutput0
SequencerOutput1
SequencerOutput2
User defined Signals
nternal Signals
Loopthroughed
Signals
9.6.2 IO Circuits
Notice
Low Active: At this wiring, only one consumer can be connected. When all Output pins
(1, 2, 3) connected to IO_GND, then current flows through the resistor as soon as one
Output is switched. If only one output connected to IO_GND, then this one is only us-
able.
The other three outputs are not usable and may not be connected (e.g. IO Power V
CC
)!
IO Power VCC
4
6
5
I
OUT
R
L
*)
I
OUT
I
OUT
R
L
*)
R
L
*)
1
8
3
In 1
IO Ground
cu rent limiter
cable term na ion
I
IN
Out 1
Out 2
Out
(Line2)
(Line1)
(Line3)
(Line0)
3
*) resistor must be used, I
Out
= 16 mA
by U
EXT
= 24 VDC recommended,
drawing shown above example
for using high active signal
Figure 31 ►
IO matrix of the
Baumer VLU on the out-
put side.
Summary of Contents for USB3 Vision
Page 2: ...2 ...
Page 5: ...5 15 Warranty Notes 57 16 Support 57 17 Conformity 17 1 CE 17 2 RoHS ...
Page 59: ...59 ...