8.3.3.3 Overlapped Operation: t
exposure(n+2)
< t
exposure(n+1)
If the exposure time (t
exposure
) is decreased from the current acquisition to the next acquisi-
tion, the time the camera is unable to process occurring trigger signals (t
notready
) is scaled
up accordingly.
If the t
exposure
is decreased to the extent that t
notready
exceeds the pause between two incom-
ing trigger signals, the camera is unable to process this trigger and image acquisition will
not start (the trigger will be skipped).
Exposure
Readout
t
exposure(n)
t
readout(n+1)
t
readout(n)
t
exposure(n+1)
t
exposure(n+2
t
triggerdelay
t
min
Trigger
Flash
t
flash(n)
t
flashdelay
t
flash(n+1)
TriggerReady
t
notready
Notice
Above a certain frequency of trigger signal, skipping triggers becomes unavoidable. In