4.3.3.2
Release Delay Time
The release delay time defines the time, where the measurement value needs to be below (single point) or
outside (window mode) of the switchpioints of the related SSC, until its status is changed to inactive (or
active, if the logic is inverted as described in section 4.3.2.1)
When to apply?
-
To avoid false switching operations in case of an object which is not 100% stable to detect over the
whole length
-
To supress short losses of a proper signal due to known disturbances such as the wheel of a mixer
.
-
To avoid bouncing.
-
To optimize the timing of the execution of a subsequent actor triggered by the output of the sensor.
-
To detect a unwanted gap size within a continuous flow of products.
Figure 19: Release Delay
Parameter name
Short Description
Rights
Unit / Allowed
values
Release Delay.SSC1 Time
Sets the release delay time,
Available for SSC1 and SSC4
rw
0 to 60.000 ms