Line 11
PC - Main counter (current counter status)
Line 12
P1 - Preset value 1
Line 13
P2 - Preset value 2
Line 14
SC - Start count
Line 15
∑ - Totalizer
Line 16
- Hour counter
Line 17
SF - Scaling factor
The dash line indicates the end of the second programming field.
Programming field 3
The machine-dependent functions and values, as well as the inter-
face parameters are programmed here.
Default settings are always printed with * .
Line 22
Operating mode Main counter
0 * Step preset
1 Main preset
2 Parallel comparsion
3 P1 - Self-adjusting preset
Line 24
Decimal point for XP, P1, P2, SC, ∑
0 * no decimal point
1 00000.0
2 0000.00
3 000.000
4 00.0000
Line 25
Counting mode
0 * Track A UP/Down signal on track B
1 Differential counting track A adding track B subtracting (A-B)
2 Totalizing, tracks A and B adding (A+B)
3 Track A 90° track B single evaluation
4 Track A 90° track B twofold evaluation
5 Track A 90° track B fourfold evaluation
With the counting mode “Track A 90° track B“ the frequency of
track. A and B (line 26 and 27) is set to 10 kHz.